Hot air for a large-scale drying operation is to be produced by routing the air over a tube bank (unmixed), while products of combustion are routed through the tubes. The surface area of the cross-flow heatexchanger is
(a) What are the air and gas outlet temperatures?
(b) After extended operation, deposits on the innertube surfaces are expected to provide a foulingresistance of
(c) The heat exchanger performance may be improved by increasing the surface area and/or the overall heat transfer coefficient. Explore the effect of such changes on the air outlet temperature for
Want to see the full answer?
Check out a sample textbook solutionChapter 11 Solutions
Fundamentals of Heat and Mass Transfer
Additional Engineering Textbook Solutions
Engineering Mechanics: Statics & Dynamics (14th Edition)
Foundations of Materials Science and Engineering
Manufacturing Engineering & Technology
Mechanics of Materials
Degarmo's Materials And Processes In Manufacturing
Vector Mechanics For Engineers
- Water flowing in a long, aluminum lube is to be heated by air flowing perpendicular to the exterior of the tube. The ID of the tube is 1.85 cm, and its OD is 2.3 cm. The mass flow rate of the water through the tube is 0.65kg/s, and the temperature of the water in the lube averages 30C. The free-stream velocity and ambient temperature of the air are 10m/sand120C, respectively. Estimate the overall heat transfer coefficient for the heat exchanger using appropriate correlations from previous chapters. State all your assumptions.arrow_forwardCatalogue data of a water-cooled condenser of a manufacturer gives the following details: Condensing temperature 48.9°C Water inlet temperature 37.8°C Water flow rate 20.694 kg/s Capacity 145 tons Estimate the capacity of this condenser with the same water flow rate but with an inlet temperature of 30°C and a condensation temperature of 42°C. The evaporation temperature may be assumed to be constant at 2.2°C.arrow_forwardthe stack gas from a chemical operation contain vapors tha must be condensed by lowering its temperature from 315 to 35c. the gas flow rate is 0.70 m/sec. water is vailable at 10C and 1.26 kg/sec. A two shell and 4 pass tube counterflow heat exchange will be used with a water flowing through the tubes. the gas has aspecific heat of 1.10 kj/kg-k and a gas constant of 0.36 kj/kg-k. calculate the LMTD.arrow_forward
- The evaporator section of a heat pump is installed in a large tank of water, which is used as a heat source during the winter. As energy is extracted from the water, it begins to freeze, creating an ice/water bath at 0°C, which may be used for air conditioning during the summer. Consider summer cooling conditions for which air is passed through an array of copper tubes, each of inside diameter D = 59 mm, submerged in the bath. (a) If air enters each tube at a mean temperature of Tm,i = 25°C and a flow rate of m·=0.01 kg/s, what tube length L is needed to provide an exit temperature of Tm,o = 16°C? With 10 tubes passing through a tank of total volume V = 11 m3, which initially contains 83% ice by volume, how long would it take to completely melt the ice? The density and latent heat of fusion of ice are 933 kg/m3 and hsf = 3.34 × 10^5 J/kg, respectively.arrow_forwardEstimate the heat exchanger area needed to cool 55,000 lb/hr of a light oil (specific heat= 0.74 Btu/lb°F) from 190°F to 140°F using cooling water that is available at 50°F. Thecooling water can be allowed to heat to 90°F. An initial estimate of the Overall HeatTransfer Coefficient is 120 Btu/hr.ft².°F. Show a schematic of the heat exchanger. Estimate the required mass flow rate of cooling water. The LMTD Taking the shell and tube heat exchanger described above how manytubes of 3 inch diameter and 10 ft length should be used?arrow_forwardYou as a Biochemical Engineer in an ezyme industries is assigned to handle a counter flow double pipe heat exchanger with A,= 9 m2 which used for cooling a fermentation broth (c, = 3.15 kJ/kg. K) at a rate of 10 kg/s with an inlet temperature of 90°C. The water used as coolant enters the heat exchanger at a rate of 8 kg/s with an inlet temperature of 10°C. The plant data gave the following equation for the overall heat transfer coefficient (in W/m².K): 600 %3D 1 2 • U.8 |m. where m. and m, are the cold and hot stream flow rates in kg/s, respectively.arrow_forward
- 9. A 0.013 m- o.d., 1.5-m-long tube is to be used to be condense steam at 40,000 N/m², Tsar= 349 K. Assume that the average tube-wall temperature is 325 K.The average convection coefficient for this tube in the horizontal position. is; a. 9000W/m² K b. 6700 W/m²K c. 10,500 W/m² K d. 13,500 W/m² Karrow_forwardWhat is the rate of rice husk consumption of a 2-ton grain dryer requiring to dry paddy from 22 to 14% in 8 hrs. The dryer overall thermal efficiency is 45%. Assume a heat of vaporization for paddy of 600 kCal/kg of moisture evaporated and heating value for rice husk of 3,000 kcal/kg.arrow_forward6. Н.W A furnace is to be designed for a heat duty of 30 x 10° Btu/hr and efficiency of 75%. The furnace is fired with gaseous fuel at a rate of 17 lb air/lb fuel (NHV=17000 Btu/lb). The tubes are arranged in two rows and are of 5 inch out diameter OD. With 40 ft length and 2×OD center to center Spacing, heat rate of 35000 Btu/hr of projected area is recommended. Calculate: 1) Percentage of heat absorbed in radiation section (R%). 2) The number of tubes in the radiation section. 3) Heat absorbed in the convection section. (State any assumptions used).arrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning