A household refrigerator operates with cold- and hot-temperature reservoirs of
Want to see the full answer?
Check out a sample textbook solutionChapter 1 Solutions
Introduction to Heat Transfer
Additional Engineering Textbook Solutions
Applied Statics and Strength of Materials (6th Edition)
Engineering Mechanics: Dynamics (14th Edition)
Fundamentals Of Thermodynamics
INTERNATIONAL EDITION---Engineering Mechanics: Statics, 14th edition (SI unit)
Engineering Mechanics: Statics
Thinking Like an Engineer: An Active Learning Approach (3rd Edition)
- Refrigerators currently being manufactured in the United States are using______as their refrigerant.arrow_forwardGeothermal heat pumps, or water-source heat pumps, are classified as either _____loop or _____loop systems.arrow_forwardWhy is it important to clean the condenser coils of a household refrigerator a few times a year? Also, why is it important not to block airflow through the condenser coils?arrow_forward
- A A Single system has a cooling capacity of 6 tons. The discharge of the evaporator is at -20°C & 0.1 MPa and the discharge of the condenser is at 30°C & 1.0 MPa. Determine the following: (a) the COP of the system, (b) the Energy Efficiency Ratio in kJ/hr/W, (c) the HP/ton of the system, (d) the Refrigerating Efficiency of the system. Stage Vapor Compression (SSVC) refrigeration 20 우 6 4 + - 150 140- 170- T = 160°C OL 국100- 06- s= 2.30 kJ/(kg-k) 09 006 220 4- 30: 0001 00 08 1050 06 0g Saturated Vapor 60 09 8'0 1200 1.70 - 09'1 0.7 1250 90 1.50- 1.40 OL- 1350 8-1.30 - 07- 00L 0E 1.20 FOL -50 1450 09- 1.10 T=-40°C 00'L =08'0= Saturated Liquid 20 -06'0 4. 2. 0.80 0.70 1 PRESSURE, MPa 250 350 009 150 008 00L 007 R-134a 0.2 0.2 2.0 0.04 20'0 zo'o 0.01 009 00S 002 008 001 € Tiliner-Roth and Baehr (1994 ENTHALPY, kJ/kg o paseg SIN m paynduoo saguadodarrow_forwardA parameter used to characterize the heat pump cycle performance is called the thermal efficiency. True or False?arrow_forwardAn inventor claims to have developed a refrigeration unit that maintains a cold space at - 100°C while operating in a room where the temperature is 25°C, and which has a coefficient of performance (COP) of 6.5. Evaluate whether constructing such a unit is possible.arrow_forward
- Define the Performance of Refrigerators, Air Conditioners, and Heat Pumpsarrow_forwardWHAT IS THE COEFFICIENT OF PERFORMANCE OF THE REFRIGERATOR? (please only answer if you are 100% correct)(show work)arrow_forwardA refrigeration unit absorbs 1 kW of heat from the cold reservoir and rejects 1.3kW of heat to the warm reservoir. What is the unit's coefficient of performance?arrow_forward
- A refrigeration system is to be designed to maintain the temperature in the range of -15°C to -5°C, while the outside temperature varies from 15°C to 25°C. The total thermal load on the storage unit is given as 20 kW. Obtain an initial design for the vapor compression refrigeration system shown below. For safe operation and other factors, such as additional energy transfer, design the system using a safety factor of 1.3 such that QL = 26 kW. The compressor efficiency could range from 60 to 80 percent. Using ammonia (NH3) as the working fluid: 1. Determine the temperatures and pressures at the different points in the cycle (points 1, 2, 3, and 4). 2. Determine the coefficient of performance value and the mass flow rate of the working fluid. Please provide picture of tables if usedarrow_forwardThermodynamics: A refrigeration unit using Refrigerant-134a is used to maintain a certain space at –15°C. The condenser rejects heat (?H) to cooling water that enters the condenser at 15°C at a rate of 0.2 kg/s and leaves at 35°C (all as saturated liquid water). The superheated refrigerant enters the condenser at 0.8 MPa and 40°C and leaves as a saturated liquid at the same temperature. If the compressor consumes 4.5 kW of power, determine (a) the mass flow rate of the refrigerant, (b) the refrigeration load (?̇L), (c) the COP.arrow_forwardA refrigeration system is to be designed to maintain the temperature in the range of -15°C to -5°C, while the outside temperature varies from 15°C to 25°C. The total thermal load on the storage unit is given as 20 kW. Obtain an initial design for the vapor compression refrigeration system shown below. For safe operation and other factors, such as additional energy transfer, design the system using a safety factor of 1.3 such that QL = 26 kW. The compressor efficiency could range from 60 to 80 percent. As part of the design, you should: 1. Specify and justify the constraints (isentropic efficiency, condenser, and evaporator temperature) you chose. 2. Show the cycle in relation to the two-phase region on a temperature-entropy (T-s) diagram. Please upload picture of tables if any are usedarrow_forward
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage LearningRefrigeration and Air Conditioning Technology (Mi...Mechanical EngineeringISBN:9781305578296Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill JohnsonPublisher:Cengage Learning