Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
9th Edition
ISBN: 9781259989452
Author: Hayt
Publisher: Mcgraw Hill Publishers
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 12, Problem 42E
(a)
To determine
The line voltages and the phase currents for the delta connection.
(b)
To determine
The line voltages and the phase currents for the star connection.
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
15) Kirchhoff's Voltage Law (KVL) states that
A) the product of the phasor voltages around any closed path must equal zero.
B) the sum of the phasor voltages around any closed path does not have to equal zero.
C) the sum of the phasor voltages around any closed path must equal zero.
D) the sum of the phasor voltages around a closed path cannot include "through the air."
13. In parallel-connected ac circuit, the total current though the circuit is always equal to the phasor sum of the individual current though each element.
True
False
14. In a R-C parallel circuit, R=10 ohms and Xc=10 ohms, the applied voltage is leading to the circuit total current by 45 degrees (assumed applied voltage is the reference).
True
False
15. In a R-C series circuit, applied voltage is in phase with the total current.
True
False
Two impedances consist of resistance of (15 ohms and series connectedinductance of 0.04 henry) and (resistance of 10 ohms, inductance of 0.1 henryand a capacitance of 100 microfarad, all in series) are connected in series andare connected to 230 volts, 50 – Hz AC source. Find: (a) current drawn, (b) voltageacross each impedance, (c) individual and total power factor. Draw the phasordiagram.
Chapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Ch. 12.1 - Let and . Find (a) Vad; (b) Vbc; (c) Vcd.Ch. 12.2 - Prob. 2PCh. 12.2 - Modify Fig. 12.9 by adding a 1.5 resistance to...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - Three balanced Y-connected loads are installed on...Ch. 12.4 - Each phase of a balanced three-phase -connected...Ch. 12.4 - Prob. 8PCh. 12.5 - Determine the wattmeter reading in Fig. 12.24,...Ch. 12.5 - Prob. 10P
Ch. 12 - Prob. 1ECh. 12 - Prob. 2ECh. 12 - Prob. 3ECh. 12 - Describe what is meant by a polyphase source,...Ch. 12 - Prob. 5ECh. 12 - Prob. 6ECh. 12 - Prob. 7ECh. 12 - Prob. 8ECh. 12 - Prob. 9ECh. 12 - Prob. 10ECh. 12 - The single-phase three-wire system of Fig. 12.31...Ch. 12 - Prob. 12ECh. 12 - Referring to the balanced load represented in Fig....Ch. 12 - Prob. 14ECh. 12 - Prob. 15ECh. 12 - Consider a simple positive phase sequence,...Ch. 12 - Assume the system shown in Fig. 12.34 is balanced,...Ch. 12 - Repeat Exercise 17 with Rw = 10 , and verify your...Ch. 12 - Prob. 19ECh. 12 - Prob. 20ECh. 12 - Prob. 21ECh. 12 - Prob. 22ECh. 12 - A three-phase system is constructed from a...Ch. 12 - Prob. 24ECh. 12 - Each load in the circuit of Fig. 12.34 is composed...Ch. 12 - Prob. 26ECh. 12 - Prob. 27ECh. 12 - A three-phase load is to be powered by a...Ch. 12 - For the two situations described in Exercise 28,...Ch. 12 - Prob. 30ECh. 12 - Prob. 31ECh. 12 - Prob. 32ECh. 12 - Repeat Exercise 32 if Rw = 1 . Verify your...Ch. 12 - Prob. 34ECh. 12 - Prob. 35ECh. 12 - Prob. 36ECh. 12 - A wattmeter is connected into the circuit of Fig....Ch. 12 - Find the reading of the wattmeter connected in the...Ch. 12 - (a) Find both wattmeter readings in Fig. 12.39 if...Ch. 12 - Circuit values for Fig. 12.40 are , , , , . Find...Ch. 12 - Prob. 41ECh. 12 - Prob. 42ECh. 12 - (a) Is the load represented in Fig. 12.41...Ch. 12 - Prob. 44E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In a R-C parallel circuit, total current is out of phase with the applied voltage." True False In a R-C parallel circuit, total current is out of phase with the applied voltage." True False In parallel-connected ac circuit, the value of the equivalent admittance of the circuit is equal to the phasor sum of the reciprocal of the individual admittances. " True Falsearrow_forwardThe impedance Z1 = 6+j8, Z2 = 8 -j6 and Z3 = 10+j0 ohms measured at 50Hz from three branches of a parallel circuit. This circuit is fed from a 100-volt 50-Hz supply. A purely reactive (inductive or capacitive) circuit is added as the fourth parallel branch to the above three-branched parallel circuit so as to draw minimum current from the source. Determine the value of L or C to be used in the fourth branch and also find the minimum current.arrow_forward3. In a R-C parallel circuit, total current is out of phase with the applied voltage. True False 5. In a R-C series circuit, total current is out of phase with the applied voltage. True False 6. In series-connected ac circuit, the value of the equivalent admittance of the circuit is equal to the reciprocal of phasor sum of the reciprocal of the individual admittances. True Falsearrow_forward
- A balanced load is connected in star across a 3 phasec415V 50Hz supply. The load consists of a coil of resistance 25 ohms and inducrance 0.5 henry in paeallel with a purw resistance of 28 ohms and a pure capaciror of 60microfarads capacitance ,in each branch. Calculate a. The line currents? Need full working and answer has to be 9.3A Formola for inductance XL= 2×3.142FL FORMOLA FOR CAPACITOR XC= 1/2×3.142×FCarrow_forwardA three-phase circuit is balanced. The source voltage for the a-phase has a magnitude of 100 volts, and you can assume the phase angle is a reference of 0 degrees. Write the phasor expressions with proper subscript notation for the source voltage for each leg of the three-phase source if it is in a positive phase sequence.arrow_forwardThe circuit shows an unbalanced electrical installation powered by a positive sequence symmetrical three-phase network of 380 V compound voltage. The loads are single phase. Load 1 absorbs an active power of 950 W with f.d.p. 0.5 inductive. Load 2 absorbs an active power of 1,140 W with f.d.p. Unit. Load 3 absorbs from the network an active power of 760 W with f.d.p. 0.5 capacitive. Taking the network voltage URN as the phase reference, calculate: a) complex expressions of the line currents IR. Is. and ITarrow_forward
- Analysis Problems: Prob 1. What will happen in each of these systems to the phase voltages of the load, if one of the source phases fails open? Source Load Winding fails open! Source Load Winding fails open!arrow_forwardThe circuit shows an unbalanced electrical installation powered by a positive sequence symmetrical three- phase network of 380 V compound voltage. The loads are single phase. Load 1 absorbs an active power of 950 W with f.d.p. 0.5 inductive. Load 2 absorbs an active power of 1,140 W with f.d.p. Unit. Load 3 absorbs from the network an active power of 760 W with f.d.p. 0.5 capacitive. Taking the network voltage URN as the phase reference, calculate: a) complex expressions of the line currents IR. Is. and IT RO- SO TO IR Is IT U₁-380 V CARGA 1 P₁ =950 W cos p1=0,5 ind. CARGA 2 P₂=1.140 W cos p₂=1 CARGA 3 P3=760 W cos p3=0,5 cap.arrow_forwardA balanced load is connected in star across a 3 phasec415V 50Hz supply. The load consists of a coil of resistance 25 ohms and inducrance 0.5 henry in paeallel with a purw resistance of 28 ohms and a pure capaciror of 60microfarads capacitance ,in each branch. Calculate a. The line currents The answer has to be 9.3Aarrow_forward
- Please answer quickly "In a R-L series circuit, applied voltage is in phase with the total current." True False "In series-connected ac circuit, the total voltage across the circuit and the voltage across each elements are the same." True False "In parallel-connected ac circuit, the total voltage across the circuit is always equal to the phasor sum of the individual voltage across each element." True Falsearrow_forwardAn 11 kV generating station has four identical 3-phase alternatorsGl, G2, G3 and G4 each of L0 MVA capacity and l2%o reaclarce.There are two section of bus-bar P and Q, linked by a reactor X ratedat 10 MVA with 24o/oreactance. From section Q load is taken througha 6 MVA, i 1kV/66kV step-up transformer (T1) having a reactance of37o. Determine the fault current if a three-phase short-circuit occursnear the high voltage terminal of the transformer (F) as shown inFigure.Assume prefault voltages to be 1 pu and prefault currents to be zeroarrow_forwardThree impedances (4-j6) ohm, (6+j8) ohm, and (5-j3) ohms are connected in parallel. Calculate the current in each branch when the total supply current is 20 A. Please provide its solution...its urgently needed...please.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning
How do Electric Transmission Lines Work?; Author: Practical Engineering;https://www.youtube.com/watch?v=qjY31x0m3d8;License: Standard Youtube License