Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
9th Edition
ISBN: 9781259989452
Author: Hayt
Publisher: Mcgraw Hill Publishers
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 12, Problem 14E
(a)
To determine
The current flowing through the neutral wire when
(b)
To determine
The new value of
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
VR₂
+
EQ-6 V
R₂ € 8.2 ΚΩ
aon
R₁
L
ell m
FIG. 12.75
Problem 18.
IL
6.8 ΚΩ
5 mH VL
*18. For the network of Fig. 12.75:
a. Write the mathematical expression for the current i
and the voltage v₁ following the closing of the switch.
b. Determine the mathematical expressions for i, and V₁
if the switch is opened after a period of five time con-
stants has passed.
c. Sketch the waveforms of i, and v, for the time peri-
ods defined by parts (a) and (b).
d. Sketch the waveform for the voltage across R₂ for the
same period of time encompassed by i and v₁. Take
careful note of the defined polarities and directions of
Fig. 12.75.
12.31. How would you realise a terminal voltage of 10 V using solar cells of the
type characterised in Fig. 12.20?
*25. For the network of Fig. 12.80, the switch is closed at
t = 0 s.
a. Determine V at t = 25 ms.
b. Find Vz at t = 1 ms.
c. Calculate VR, at t = 17.
VR
100 N
E 36 V
R
470 2
L
0.6 H
VL
R3
20 Ω
VR3
FIG. 12.80
Chapter 12 Solutions
Loose Leaf for Engineering Circuit Analysis Format: Loose-leaf
Ch. 12.1 - Let and . Find (a) Vad; (b) Vbc; (c) Vcd.Ch. 12.2 - Prob. 2PCh. 12.2 - Modify Fig. 12.9 by adding a 1.5 resistance to...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - A balanced three-phase three-wire system has a...Ch. 12.3 - Three balanced Y-connected loads are installed on...Ch. 12.4 - Each phase of a balanced three-phase -connected...Ch. 12.4 - Prob. 8PCh. 12.5 - Determine the wattmeter reading in Fig. 12.24,...Ch. 12.5 - Prob. 10P
Ch. 12 - Prob. 1ECh. 12 - Prob. 2ECh. 12 - Prob. 3ECh. 12 - Describe what is meant by a polyphase source,...Ch. 12 - Prob. 5ECh. 12 - Prob. 6ECh. 12 - Prob. 7ECh. 12 - Prob. 8ECh. 12 - Prob. 9ECh. 12 - Prob. 10ECh. 12 - The single-phase three-wire system of Fig. 12.31...Ch. 12 - Prob. 12ECh. 12 - Referring to the balanced load represented in Fig....Ch. 12 - Prob. 14ECh. 12 - Prob. 15ECh. 12 - Consider a simple positive phase sequence,...Ch. 12 - Assume the system shown in Fig. 12.34 is balanced,...Ch. 12 - Repeat Exercise 17 with Rw = 10 , and verify your...Ch. 12 - Prob. 19ECh. 12 - Prob. 20ECh. 12 - Prob. 21ECh. 12 - Prob. 22ECh. 12 - A three-phase system is constructed from a...Ch. 12 - Prob. 24ECh. 12 - Each load in the circuit of Fig. 12.34 is composed...Ch. 12 - Prob. 26ECh. 12 - Prob. 27ECh. 12 - A three-phase load is to be powered by a...Ch. 12 - For the two situations described in Exercise 28,...Ch. 12 - Prob. 30ECh. 12 - Prob. 31ECh. 12 - Prob. 32ECh. 12 - Repeat Exercise 32 if Rw = 1 . Verify your...Ch. 12 - Prob. 34ECh. 12 - Prob. 35ECh. 12 - Prob. 36ECh. 12 - A wattmeter is connected into the circuit of Fig....Ch. 12 - Find the reading of the wattmeter connected in the...Ch. 12 - (a) Find both wattmeter readings in Fig. 12.39 if...Ch. 12 - Circuit values for Fig. 12.40 are , , , , . Find...Ch. 12 - Prob. 41ECh. 12 - Prob. 42ECh. 12 - (a) Is the load represented in Fig. 12.41...Ch. 12 - Prob. 44E
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 13. In parallel-connected ac circuit, the total current though the circuit is always equal to the phasor sum of the individual current though each element. True False 14. In a R-C parallel circuit, R=10 ohms and Xc=10 ohms, the applied voltage is leading to the circuit total current by 45 degrees (assumed applied voltage is the reference). True False 15. In a R-C series circuit, applied voltage is in phase with the total current. True Falsearrow_forwardExample 2.4: For a given circuit shown in Figure below, find out the equivalent resistance between terminals X and Y. 12.52 ww 202N ,202 Xo A ww 202 2022 RẠC = 250 RBp = 200 ww 12.52arrow_forwardIn a star connected system the phase currents are = 40 30° I,= 40 60° and I =40 45 ut of The current flowing through neutral wire IN is estion 84.04 9.342 A ZERO IN 13.64 A O IN = 9.342 84.04° A For a 3-phase ac device, full load current is 40A, line voltage is 450V and reactance value is 0.06Q, then percentage reactance of this device is O 0.533 % 0.307 % 6% 0.923 % 底 ) 。 IIarrow_forward
- (a) The voltage v across a load and the current i into the positive-polarity terminal are as follows (where wi andws) are not equal : v(t) = Vo + V2V1 cos(wit) + V2V1 sin(wit) + V2V3 cos(wzt) i(t) = Io + V21, cos(wit) + v213 cos(wzt – 03) V A Calculate the following: i. the average power P supplied to the load ii. the rms value of v(t) and i(t) iii. the power factor at which the load is operatingarrow_forwardElectric Machine-check image, all question there. Consider the above equivalent circuit of IM. A three phase, Y connected , 215 V (line to line), 7.5Kw , 60Hz , three pole IM has the following parameter values in Ω/phase referred to the stator R1=0.294Ω , R2=0.144 Ω, X1=0.203 Ω, X2=0.409 Ω, Xm=10.25 Ω The total friction , windage and core losses may be assumed to be constant at 350W independent of load, For a slip s=0.02, compute the followings a)Stator current b)Power factor(pf) c)Rotor speed d)Power Output(shaft) e)Output(shaft) torque f)Efficiencyarrow_forwardParagraph Styles Editing Voice Sensitvity Ed A balanced load connected to a three-phase supply comprises three identical coils in star. The line current is 25Amps.KVA input is 20 and KW input is 11.Find KVAR input, Phase voltage, line voltage ,resistance and reactance of each coil of the load. DFocus ted Statesarrow_forward
- E) Vresistor on the load is 32. Solve for following if the 3-phase transfemer configuration in Figure 6 on Worksheet 3 has the givens as listed below: a) 2A b) 4A E-line on high side = 480 V = 2:1/coil c) 6.93A d) 12A Tums ration Resistance per load - 100 Eficiency F) 1-line on the low side is = 100% a) 2A b) 4A c) A) Elcoil on the high side is 6.93A d) 12A a) 480V b) 240V G) l-phase on the low side is c) 120V a) 2A d) 69.28V b) 4A c) d) 6.93A B) Elcoil on the low side is 12A H) /coil on the low side is a) 480V b) 240V c) 120V d) 69 28V a) 2A Б) 4A c) d) 6.93A 12A C) E-phase on the low side is I) I-phase on the high side is a) b) c) 2A d) 1A a) 480V b) 240V c) 120V d) 69.28V 1.73A 4A J) I-line on the high side is D) Eresistor of the load is a) b) IA 1.73A c) 2A a) 480V b) 240V c) 120V d) 6928V d) 4A K) VA/phase of the load is a) 120VA b) 360VA c) 480VA d) 1440VA L) 3-phase VA on the high side is a) 120VA b) 360VA c) 480VA d) 1440VAarrow_forwardHomework problem: The per-phase equivalent circuit parameters of a 400 V, 33 kW, 60 Hz, star-connected, 4 pole, 1755 rpm 3-0 IM are: R1= 0.2 N, X1= j0.5 2, Xm= j20 2, R2 = 0.12, X2 = 0.2 N. If the mechanical losses (windage and friction) are 650 W and iron losses are 300 W, determine the following when the motor operates at full load at rated speed: (a) The synchronous speed. (b) The slip. (c) The input current and power factor. (d) The input power. (e) The useful mechanical power. (f) The output torque. (g) The motor efficiency. Use exact equivalent circuit and simplified equivalent circuit and give comments on the results obtained.arrow_forwardQ12: A. Explain the relation between current and voltage in the basic component of electrical circuit. B. Find the equivalent resistance of the circuit given in figure 12 1.between A and B 2.between E and F Fig 12 42 B 10arrow_forward
- A 300 m ring distributor has loads as shown in Figure below, where distances are in meters. The resistance of each conductor is 0.22 per 1000 meters, and the loads are tapped off at points B, C and D as shown. If the distributor is fed at A at 240 V, find voltages at B, C and D. 50 A 70 D 90 240 V A с 70 A 6 60 B 80 100 Aarrow_forwardHomework problem: The per-phase equivalent circuit parameters of a 400 V, 33 kW, 60 Hz, star-connected, 4 pole, 1755 rpm 3-0 IM are: R1= 0.2 Q, X1= j0.5 2, Xm= j20 Q, R½ = 0.1 2 , X2 = 0.2 N. If the mechanical losses (windage and friction) are 650 W and iron losses are 300 W, determine the following when the motor operates at full load at rated speed: (a) The synchronous speed. (b) The slip. (c) The input current and power factor. (d) The input power. (e) The useful mechanical power. (f) The output torque. (g) The motor efficiency. %3Darrow_forwardIn a R-C parallel circuit, total current is out of phase with the applied voltage." True False In a R-C parallel circuit, total current is out of phase with the applied voltage." True False In parallel-connected ac circuit, the value of the equivalent admittance of the circuit is equal to the phasor sum of the reciprocal of the individual admittances. " True Falsearrow_forward