Principles of Instrumental Analysis
7th Edition
ISBN: 9781305577213
Author: Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 20, Problem 20.2QAP
Interpretation Introduction
Interpretation:
The difference between the spectra of EI, field ionization and the CI sources is to be stated.
Concept introduction:
Ionization refers to the process in which an atom or a molecule obtains a positive or a negative charge by losing or gaining an electron. This results in the synthesis of an ion. There are a variety of ionization methods. These include chemical ionization, electron impact, electrospray ionization, field ionization etc.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Explain why an internal standard is required during sample preparation in quantitative analysis when using atomic spectroscopy?
1. State the difference between transmittance, absorbance, molar absorptivity, and
fluorescence. Which one(s) is proportional to analyte concentration?
Which method, AES or XPS, is better for resolving chemical shifts and why?
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.Similar questions
- O Macmillan Learning Co(II) was used as an internal standard to analyze a sample of Ti(IV) with atomic absorption spectroscopy (AAS). A standard mixture containing 1.30 µg Co/mL and 1.48 µg Ti/mL measured by AAS produced a signal-to-signal ratio of 2.13 Ti : 1.00 Co. A mixture was prepared by combining 5.50 mL of a Ti(IV) solution of unknown concentration with 3.50 mL of a 13.4 µg/mL solution of Co(II). The absorbance of the mixture at the Ti(IV) wavelength was 0.139 and the absorbance at the Co(II) wavelength was 0.208. Determine the concentration, in moles per liter, of Ti(IV) in the original unknown solution. concentration: M Ti(IV)arrow_forwardWhat is the Molar Absorption Coefficient for Fe(SCN)2+ (M/cm) if the path length of vial is 2.24cm and given the data in the pictures.arrow_forwardExactly 5.00 mL aliquots of a solution containing analyte X were transferred into 50.00-mL volumetric flasks and the pH of the solution is adjusted to 9.0. The following volumes of a standard solution containing 2.00 µg/mL of X were then added into each flask and the mixture was diluted to volume: 0.000, 0.500, 1.00, 1.50 and 2.00 mL. The fluorescence of each of these solutions was measured with a fluorometer, and the following values were obtained: 3.26, 4.80, 6.42, 8.02 and 9.56, respectively. ii. Using relevant functions in Excel, derive a least-squares equation for the data, and use the parameters of this equation to find the concentration of the phenobarbital in the unknown solution.arrow_forward
- As pH changes, ho will absorbance change t the wavelength of the isosbestic point?arrow_forwardIn a Stern-Volmer plot, what is the source of the largest fluorescence signal? 1.6 Ky=(1.35 ± 0.05)10°M" 1.4- 1.2 - 1.0 0.5 1.0 1.5 2.0 2.5 3.0 Concentration [µM] A. The solution at 0.5 micoMolar B. The solution at 3.0 microMolar C. The Blank FO/Farrow_forwardInduction coupled plasma (ICP) emission spectrometry is widely used for the sensitive multi-element determinations. How does the ICP work?arrow_forward
- "[FeSCN2+]eq is calculated using the formula: [FeSCN2+]eq = Aeq/Astd x [FeSCN2+]std where Aeq and Astd are the absorbance values for the equilibrium and standard sample respectively." I am confused about what Aeq and Astd mean. We did an experiment where we measured the absorption of this chemical formation and I got around 0.18. Is that one of the values?arrow_forward6 Why standard solutions are used in Atomic absorption Spectroscopy (AAS) whereas UV-Vis molecular absorbance only extinction coefficient is necessary?arrow_forwardWhat is the molar extinction coefficient if the pathlength of the sample cell is 5.6mm and the absorbance of 62.5 M solution is 0.222? 6.342X10-3 L mole- cm- 6.342X10-3 L mole- mm- 6.342X10-4 L mole- mm- 6.342X10-4 L mole- cm-arrow_forward
- 6 why it makes sense to use an internal standard in IR spectrometry when its not used in Uv-Visarrow_forwardThe levels of Vitamin B1 in a sample of milk was determined using the Standard Addition method and technique of fluorescence spectroscopy. 18.0 ml of the milk sample was diluted to 20.0 ml using distilled water and then the fluorescence was measured. The resulting signal was 210 units. A spike was made by taking 18.0 ml of the same milk sample, adding 1.0 ml of a 6.0 ppm Vitamin B1 standard solution, and then diluting to 20.0 ml using distilled water. The signal of the spiked milk was 540 units. Calculate the concentration of Vitamin B1 in the original milk sample (in ppm). Report to 3 decimal places.arrow_forwardQ2/ If you know that a specific solution inside a cell is (1 cm) wide and the molar absorption coefficient (cm.mol. 4-10 and the percentage of permeability is 50%, calculate the concentration of the solution. 0.075 0.19 0.75 0.52 O 1.93arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Instrumental AnalysisChemistryISBN:9781305577213Author:Douglas A. Skoog, F. James Holler, Stanley R. CrouchPublisher:Cengage Learning
Principles of Instrumental Analysis
Chemistry
ISBN:9781305577213
Author:Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:Cengage Learning