Concept explainers
(a)
Interpretation:
The mass difference resolved at
Concept introduction:
The mass difference can be calculated as the ratio of nominal mass of the first peak and the resolution.
(b)
Interpretation:
The mass difference resolved at
Concept introduction:
The mass difference can be calculated as the ratio of nominal mass of the first peak and the resolution.
(c)
Interpretation:
The mass difference resolved at
Concept introduction:
The mass difference can be calculated as the ratio of nominal mass of the first peak and the resolution.
(d)
Interpretation:
The mass difference resolved at
Concept introduction:
The mass difference can be calculated as the ratio of nominal mass of the first peak and the resolution.
Trending nowThis is a popular solution!
- Mass spectrometry is an extremely versatile detection system for GC. However, interfacing an HPLC system to a mass spectrometer is a much more difficult task. Describe the major reasons why it is more difficult to combine HPLC with mass spectrometry than it is to combine GC with mass spectrometry.arrow_forwardThe chemical shift (ppm) of a sample is independent of the magnetic strength of a spectrophotometer in NMR. O True O Falsearrow_forwardCalculate the resolution required to resolve peaks for N2+ (MW = 28.0061) and CO+ (MW = 27.9949)arrow_forward
- If two signals differ by 90 Hz in a 300 MHz spectrometer, by how much do they differ in a 500 MHzspectrometer?arrow_forwardThe chemical shift value (δ) is measured by the ratio of shift in Hertz and the operational frequency of the spectrometer in MHz, give the equation to calculate the shift valuearrow_forwardIf two signals differ by 1.5 ppm in a 300 MHz spectrometer, by how much do they differ in a 500 MHz spectrometer?arrow_forward
- which of the following statements is incorrect? A. a conventional mass spectrometer does not use a spectrophotometric detectorB. a conventional mass spectrometer does not always require high purity samplesC. a mass spectrum shows no signals due to uncharged speciesD. a conventional mass spectrometer uses high energy UV radiationarrow_forwardWhat is the resolution in ppm NO3-N of a spectrophotometer that gives a reading of 0.600 absorbance units for 25 ppm NO3-N? The resolution of the instrument is 0.001 absorbance units.arrow_forward5 What would the effect of increasing sample pressure (while maintaining a fixed cell length) have on an FTIR spectrum. By ”cell” I mean the chamber holding the gas.arrow_forward
- What is the relationship between chemical shift in ppm and operating frequency?arrow_forwardCalculate the resolution required to resolve the following peaks; i) CH3N+ (MW = 28.0187) and N2+ (MW = 28.0061) ii) C2H4+ (MW = 28.0313) and CO+ (MW = 27.9949) iii) C3H7N3+ (MW = 85.0641) and C5H9O+ (MW = 85.0653) iv) 116Sn+ (At W = 115.90219) and 232Th2+ (At W = 232.03800)arrow_forwardThe ppm concentration of Pb2+ in a blood sample were measured with Spectrophotometry. 5.00 mL of a blood sample were taken and this sample gave a signal of 0.301 a.u.. Another 5.00 mL of a blood sample were mixed with 0.50 mL og 1.75 ppm Pb2+. Then, this mixture was diluted to 25.00 mL and this diluted mixture gave a signal of 0.406 a.u.. What is the ppm concentration of a blood sample?arrow_forward