The column was packed with 12 g of alumina. A 50:50 mixture of ferrocene and acetylferrocene was weighed on the electronic balance (total mass = 0.102 g, or 102 mg), and placed at the top of the column. Elution was first with hexane, which caused a yellow band to move down the white alumina. After the yellow fraction was collected, the eluent was replaced by TBME, which was passed through the column until the red fraction was collected. The two colored solutions were heated in a 70 °C water bath until the solvents were evaporated and colored solids were obtained. Percent recoveries for each compound were calculated, and melting points were taken. Data for the first, fastest-moving fraction: 0.045 g yellow solid, mp = 170-171 °C. Data for the second, slowest-moving fraction: 0.054 g orange solid, mp= 75-80 °C.

Fundamentals Of Analytical Chemistry
9th Edition
ISBN:9781285640686
Author:Skoog
Publisher:Skoog
Chapter24: Introduction To Spectrochemical Methods
Section: Chapter Questions
Problem 24.28QAP
icon
Related questions
Question

calculate for percent recovery, and explain what does 50:50 mixture means?  since total mass is 0.102 g, does it means 0.051 for ferrocene, and another 0.051 for acetyferrocene. I feel confused.

THE EXPERIMENT:
The column was packed with 12 g of alumina. A 50:50 mixture of ferrocene and acetylferrocene was weighed
on the electronic balance (total mass = 0.102 g, or 102 mg), and placed at the top of the column. Elution was
first with hexane, which caused a yellow band to move down the white alumina. After the yellow fraction was
collected, the eluent was replaced by TBME, which was passed through the column until the red fraction was
collected. The two colored solutions were heated in a 70 °C water bath until the solvents were evaporated and
colored solids were obtained. Percent recoveries for each compound were calculated, and melting points were
taken.
Data for the first, fastest-moving fraction: 0.045 g yellow solid, mp= 170-171 °C.
Data for the second, slowest-moving fraction: 0.054 g orange solid, mp = 75-80 °C.
Transcribed Image Text:THE EXPERIMENT: The column was packed with 12 g of alumina. A 50:50 mixture of ferrocene and acetylferrocene was weighed on the electronic balance (total mass = 0.102 g, or 102 mg), and placed at the top of the column. Elution was first with hexane, which caused a yellow band to move down the white alumina. After the yellow fraction was collected, the eluent was replaced by TBME, which was passed through the column until the red fraction was collected. The two colored solutions were heated in a 70 °C water bath until the solvents were evaporated and colored solids were obtained. Percent recoveries for each compound were calculated, and melting points were taken. Data for the first, fastest-moving fraction: 0.045 g yellow solid, mp= 170-171 °C. Data for the second, slowest-moving fraction: 0.054 g orange solid, mp = 75-80 °C.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Gravimetric Analysis
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemistry and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Fundamentals Of Analytical Chemistry
Fundamentals Of Analytical Chemistry
Chemistry
ISBN:
9781285640686
Author:
Skoog
Publisher:
Cengage
Principles of Instrumental Analysis
Principles of Instrumental Analysis
Chemistry
ISBN:
9781305577213
Author:
Douglas A. Skoog, F. James Holler, Stanley R. Crouch
Publisher:
Cengage Learning