1. In order to meet an emergency, a three phase transformers bank rated at 12,470/7,200 V is connected in Delta-Wye which is fed by a 12,470 V transmission line. If the transformer bank supplies 60 MVA to a load, calculate: " a. The turns ratio for each transformer b. The currents in the primary and secondary winding of the transformer c. The primary and secondary transmission line currents

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.56P: Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit...
icon
Related questions
Question

Please answer all subpart in short I will like it please

Please all subpart please

 

1. In order to meet an emergency, a three phase transformers bank rated at 12,470/7,200 V is connected in Delta-Wye which is fed by a 12,470 V transmission line. If the
transformer bank supplies 60 MVA to a load, calculate: "
a. The turns ratio for each transformer
b. The currents in the primary and secondary winding of the transformer
c. The primary and secondary transmission line currents
2. A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 KVA and has a step-down ratio of 8:1. The bank
supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine.
a. The primary line and phase voltages
b. The secondary line and phase voltages
c. The secondary line and phase currents
d. The apparent and active power at the load
e. Total kVA capacity of the transformer
4.
Transcribed Image Text:1. In order to meet an emergency, a three phase transformers bank rated at 12,470/7,200 V is connected in Delta-Wye which is fed by a 12,470 V transmission line. If the transformer bank supplies 60 MVA to a load, calculate: " a. The turns ratio for each transformer b. The currents in the primary and secondary winding of the transformer c. The primary and secondary transmission line currents 2. A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 KVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. a. The primary line and phase voltages b. The secondary line and phase voltages c. The secondary line and phase currents d. The apparent and active power at the load e. Total kVA capacity of the transformer 4.
Expert Solution
steps

Step by step

Solved in 4 steps with 2 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning