Concept explainers
In cold weather, meteorologists report an index called the windchill factor, that takes into account the wind speed and the temperature. The index provides a measure of the chilling effect of wind at a given air temperature. Windchill may be approximated by the formula:
W=13.12+0.6215* t–11.37 *v0.16+0.3965 * t *v0.016
where
v = wind speed in m/sec
t = temperature in degrees Celsius: t <= 10
W = windchill index (in degrees Celsius)
Write a function that returns the windchill index. Your code should ensure that the restriction on the temperature is not violated. Look up some weather reports in back issues of a newspaper in your university library and compare the windchill index you calculate with the result reported in the newspaper.
Want to see the full answer?
Check out a sample textbook solutionChapter 5 Solutions
Problem Solving with C++ (10th Edition)
Additional Engineering Textbook Solutions
Programming in C
Starting Out with Python (4th Edition)
Java: An Introduction to Problem Solving and Programming (8th Edition)
Objects First with Java: A Practical Introduction Using BlueJ (6th Edition)
Starting Out with Python (3rd Edition)
Database Concepts (8th Edition)
- (Transportation) Road construction requires estimating the expected loads on a road’s pavement over its design life. A common approach for determining this information is to use ESAL values; one ESAL is the load a single 18,000-lb (80,000 N) single-axle truck applies to the road’s surface. The ESAL value for any single-axle vehicle can be approximated by this formula: ESAL=[W18,000]4 ESAL is the equivalent single-axle load. W is the vehicle’s weight (lbs). Using this formula, write, compile, and run a C++ program that determines ESAL values and use it to complete the following chart. The ESAL values should be output in a field width of 10, with six digits after the decimal point.arrow_forwardThe mitotic index is a calculated value that represents the percentage of cells in a sample that are actively dividing. It involves counting the total number of cells present including those actively dividing or those in interphase, the total number of cells that are actively dividing (not including interphase), and then calculating what percentage of the total cells are actively dividing (the percentage undergoing mitosis). The formula is: Mitotic index= # of cells in mitosis / # of cells in total x 100% Use this formula to calculate the mitotic index for the diagram seen in Question 5. Show your calculations (you can use * for multiplication and / for division if you prefer) and indicate your final answer as a percentage rounded to the nearest tenth of a percentage (1 decimal place). Note: The mitotic index seen in this simulation is much higher than you would see in a real tissue sample. The sample was simulated this way so that the counting and calculations would be easier…arrow_forwardQ3i design a program for estimate the type of fluid flow depending on Reynold mumber (Re). The type of flow can be estimated from the table below and (Re) can be cakculated from the following equation. Re- Pud Where: pis the density u is velocity d is pipe diameter u is viscosity Re no. Fluid flow type E 2300 Laminar 2300 Re-4000 Transition 24000 Turbulentarrow_forward
- Context: Measuring Air Quality Levels of various air borne pollutants such as Nitrogen Monoxide (NO), Nitrogen Dioxide (NO2) and particulate matter (also called particle pollution) are all major contributors to the measure of overall air quality. For instance, NO2 is measured using micrograms in each cubic metre of air (㎍/m3). A microgram (㎍) is one millionth of a gram. A concentration of 1 ㎍/m3 means that one cubic metre of air contains one microgram of pollutant. To protect our health, the UK Government sets two air quality objectives for NO2 in their Air Quality Strategy The hourly objective, which is the concentration of NO2 in the air, averaged over a period of one hour. The annual objective, which is the concentration of NO2 in the air, averaged over a period of a year. The following table shows the colour encoding and the levels for Objective 1 above, the mean hourly ratio, adopted in the UK. Index 1 2 3 4 5 6 7 8 9 10 Band Low Low Low Moderate Moderate Moderate High…arrow_forwardobs vaccinated 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 15 1 16 0 17 0 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 Run the excel formula =average(A:A).arrow_forward(Mechanics) The deflection at any point along the centerline of a cantilevered beam, such as the one used for a balcony (see Figure 5.15), when a load is distributed evenly along the beam is given by this formula: d=wx224EI(x2+6l24lx) d is the deflection at location x (ft). xisthedistancefromthesecuredend( ft).wistheweightplacedattheendofthebeam( lbs/ft).listhebeamlength( ft). Eisthemodulesofelasticity( lbs/f t 2 ).Iisthesecondmomentofinertia( f t 4 ). For the beam shown in Figure 5.15, the second moment of inertia is determined as follows: l=bh312 b is the beam’s base. h is the beam’s height. Using these formulas, write, compile, and run a C++ program that determines and displays a table of the deflection for a cantilevered pine beam at half-foot increments along its length, using the following data: w=200lbs/ftl=3ftE=187.2106lb/ft2b=.2fth=.3ftarrow_forward
- One way to determine how healthy a person is by measuring the body fat of the person. The formulas to determine the body fat for female and male are as follows: Body fat formula for women: A1 = (body weight x 0.732) + 8.987 A2 = wrist measurement (at fullest point)/3.140 A3 = waist measurement (at navel) x 0.157 A4 = hip measurement (at fullest point) x 0.249 A6 = forearm measurement (at fullest point) x 0.434 B = A1 + A2 A3 A4 + A5 Body fat = body weight - B Body fat percentage = body fat x 100/body weight Body fat formula for men: A1 = (Body weight x 1.082) + 94.42 A2 = wrist measurement x 4.15 B = A1 A2 Body fat = body weight B Body fat percentage = body fat x 100/body weight Write a program to calculate the body fat of a person.arrow_forward(Heat transfer) The formula developed in Exercise 5 can be used to determine the cooling time, t, caused only by radiation, of each planet in the solar system. For convenience, this formula is repeated here (see Exercise 5 for a definition of each symbol): t=Nk2eAT3fin A=surfaceareaofasphere=4r2 N=numberofatoms=volumeofthespherevolumeofanatom Volume of a sphere sphere=43radius3 The volume of a single atom is approximately 11029m3 . Using this information and the current temperatures and radii listed in the following chart, determine the time it took each planet to cool to its current temperature, caused only by radiation.arrow_forwardWhen you borrow money to buy a house, a car, or for some other purpose, you repay the loan by making periodic payments over a certain period of time. Of course, the lending company will charge interest on the loan. Every periodic payment consists of the interest on the loan and the payment toward the principal amount. To be specific, suppose that you borrow $1,000 at an interest rate of 7.2% per year and the payments are monthly. Suppose that your monthly payment is $25. Now, the interest is 7.2% per year and the payments are monthly, so the interest rate per month is 7.2/12 = 0.6%. The first months interest on $1,000 is 1000 0.006 = 6. Because the payment is $25 and the interest for the first month is $6, the payment toward the principal amount is 25 6 = 19. This means after making the first payment, the loan amount is 1,000 19 = 981. For the second payment, the interest is calculated on $981. So the interest for the second month is 981 0.006 = 5.886, that is, approximately $5.89. This implies that the payment toward the principal is 25 5.89 = 19.11 and the remaining balance after the second payment is 981 19.11 = 961.89. This process is repeated until the loan is paid. Write a program that accepts as input the loan amount, the interest rate per year, and the monthly payment. (Enter the interest rate as a percentage. For example, if the interest rate is 7.2% per year, then enter 7.2.) The program then outputs the number of months it would take to repay the loan. (Note that if the monthly payment is less than the first months interest, then after each payment, the loan amount will increase. In this case, the program must warn the borrower that the monthly payment is too low, and with this monthly payment, the loan amount could not be repaid.)arrow_forward
- T/F Manhattan distance is an alternative way to define a distance between two points.arrow_forwardPositive integer:-7.arrow_forwardEngineers use both English and SI (Système International d’Unités) units on a regular basis. Some fields use primarily one or the other, but many combine the two systems. For example, the rate of energy input to a steam power plant from burning fossil fuels is usually measured in Btu/hour. However, the electricity produced by the same plant is usually measured in joules/s (watts). Automobile engines, by contrast, are often rated in horsepower or in ft lbf/s. Here are some conversion factors relating these different power measurements: a) Generate a table of conversions from kW to hp. The table should start at 0 kW and end at 15 kW. Use the input function to let the user define the increment between table entries. Use disp and fprintf to create a table with a title, column headings, and appropriate spacing. The output should look like: kW hP 0.0 0.00 2.5 3.35 5.0. 6.70 7.5 10.06 10.0 13.41 12.5…arrow_forward
- C++ for Engineers and ScientistsComputer ScienceISBN:9781133187844Author:Bronson, Gary J.Publisher:Course Technology PtrC++ Programming: From Problem Analysis to Program...Computer ScienceISBN:9781337102087Author:D. S. MalikPublisher:Cengage LearningEnhanced Discovering Computers 2017 (Shelly Cashm...Computer ScienceISBN:9781305657458Author:Misty E. Vermaat, Susan L. Sebok, Steven M. Freund, Mark Frydenberg, Jennifer T. CampbellPublisher:Cengage Learning
- EBK JAVA PROGRAMMINGComputer ScienceISBN:9781337671385Author:FARRELLPublisher:CENGAGE LEARNING - CONSIGNMENT