The molecular weight of a polymer can be determined from its viscosity by the following relationship:
where
should yield a straight line, with a y intercept equal to
Polymer Concentration, g/dL | Efflux Time, s |
0 (pure solvent) | 83 |
0.04 | 89 |
0.06 | 95 |
0.08 | 104 |
0.10 | 114 |
0.12 | 126 |
0.14 | 139 |
0.16 | 155 |
0.20 | 191 |
Want to see the full answer?
Check out a sample textbook solutionChapter 20 Solutions
Numerical Methods for Engineers
Additional Math Textbook Solutions
Fundamentals of Differential Equations (9th Edition)
Advanced Engineering Mathematics
Basic Technical Mathematics
College Algebra (6th Edition)
- Fluid runs through a drainage pipe with a 10-cm radius and a length of 30m (3000 cm). The velocity of the fluid gradually decreases from the center of the pipe toward the edges as a result of friction with the walls of the pipe. For the data shown, v(x) is the velocity of the fluid (in. cm/sec) and x represents the distance (in. cm) from the center of the pipe toward the edge. x 0 1 2 3 4 5 6 7 8 9 v(x) 195.5 195.1 194.5 193.5 192.2 190.6 188.8 186.6 184.2 181.5 Use regression to find a quadratic function to model the data. Use all of the given data points and round each coefficient to 4 decimal places.arrow_forward6.9 In an electrophoretic fiber-making process, the diameter of the fiber, d, is related to the current flow, 1. The following are measured during production: I (NA) d (μm) 300 22 300 26 350 27 400 30 400 34 500 33 500 33.5 650 37 650 42 The relationship between the current and the diameter can be modeled with an equation of the form d = a + b.I. Use the data to determine the constants a and b that best fit the data.arrow_forwardConsider a water tank that is being filled with rainfall at the top and is drained through a small hole at the bottom. The change in volume can be modelled by considering the amount of water entering and leaving the tank (per unit of time) as follows dV dt fin - fout. Here volume of water in the tank V is in litres, flow rate in fin is in litres per hour, flow rate out fout is. in litres per hour and time t is in hours. Initially, the tank contains 50L of water: V(0) = 50. (a) Assume the rainfall throughout the day is getting heavier, such that, fin(t) = 10 + t and that the tank is losing 10% of its volume of water per hour, such that, fout (V) = 0.1V. Check by direct substitution that the function V(t) = 10(t + 5e-0.1t) satisfies the ODE and the initial condition. (b) Now assume that the hole is slowly growing in size, so that the flow rate out increases with time: fout (V, t) = 0.1(1 + 0.1t) V. Solve the ordinary differential equation for V(t) with this flow rate out, using either…arrow_forward
- What is the constant c in the equation? O a. wave speed O b. thermal diffusion coefficient O c. the displacement at time t O d. steady state distribution coefficientarrow_forwardCan you find the amount of salt A in the tank at any time t?arrow_forward2. The viscocity u of a crude oil varies with temperature Tas shown below: : 12.0 : 50.1 T 25.0 38.0 4.9 10.0 The model for viscosity is :arrow_forward
- Mist (airborne droplets or aerosols) is generated when metal-removing fluids are used in machining operations to cool and lubricate the tool and workpiece. Mist generation is a concern to OSHA, which has recently lowered substantially the workplace standard. An article gave the accompanying data on x = fluid-flow velocity for a 5% soluble oil (cm/sec) and y the extent of mist droplets having diameters smaller than 10 µm (mg/m³): 85 177 190 354 360 442 960 0.39 0.60 0.45 0.66 0.60 0.69 0.90 (a) The investigators performed a simple linear regression analysis to relate the two variables. Does a scatter plot of the data support this strategy? Yes, a scatter plot shows a reasonable linear relationship. No, a scatter plot does not show a reasonable linear relationship. (b) What proportion of observed variation in mist can be attributed to the simple linear regression relationship between velocity and mist? (Round your answer to three decimal places.) (c) The investigators were particularly…arrow_forward2.) Victor the custodian was withdrawing some cash from a local ATM when the machine malfunctioned and money began to fly out of the machine. The rate, in dollars per second, that money is coming out of the ATM is modeled by the function M'(t), where t is measured in seconds. Selected values for M'(t) are shown in the table below. t M'(t) 0 87 3 105 6 50 8 25 10 5 a.) Use a Left Riemann Sum with 4 subintervals indicated in the table to approximate the area under the curve M'(t) and above the t-axis from t = 0 to t = 10. b.) Use a Right Riemann Sum with 4 subintervals indicated in the table to approximate the area under the curve M'(t) and above the t-axis from t = 0 to t = 10. c.) Use a Midpoint Riemann Sum with 2 subintervals indicated in the table to approximate the area under the curve M'(t) and above the t-axis from t = 0 to t = 10.arrow_forward
- Calculus For The Life SciencesCalculusISBN:9780321964038Author:GREENWELL, Raymond N., RITCHEY, Nathan P., Lial, Margaret L.Publisher:Pearson Addison Wesley,Algebra & Trigonometry with Analytic GeometryAlgebraISBN:9781133382119Author:SwokowskiPublisher:CengageAlgebra: Structure And Method, Book 1AlgebraISBN:9780395977224Author:Richard G. Brown, Mary P. Dolciani, Robert H. Sorgenfrey, William L. ColePublisher:McDougal Littell
- College Algebra (MindTap Course List)AlgebraISBN:9781305652231Author:R. David Gustafson, Jeff HughesPublisher:Cengage Learning