Applied Fluid Mechanics (7th Edition)
7th Edition
ISBN: 9780132558921
Author: Robert L. Mott, Joseph A. Untener
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Chapter 10, Problem 10.55PP
To determine
To Compute:
The equivalent value of resistance coefficient
Expert Solution & Answer
Want to see the full answer?
Check out a sample textbook solutionStudents have asked these similar questions
Compute points on the velocity profile from the pipe wall to the centerline of a 3/4-in Type K copper tube if the volume flow rate of water at 60'F is Q 0.5 gal/min. Use increments of 0.05 in and include the velocity at the centerline.
please be through and provide all calculus and graphs/tables
Compute points on the velocity profile from the tube wall to the centerline of a
standard hydraulic steel tube, 50 mm OD x 1.5 mm wall, if the volume flow rate
of SAE 30 oil (sg = 0.89) at 110°C is 25 L/min. Use increments of 4.0 mm and
include the velocity at the centerline.|
Saturated water at 310K is being pumped from a tank to an elevated tank at the rate of 7L/s. All of the piping is in 5-in. schedule 40 steel pipe. If the 2 fittings used is 90° ell standard long radius, The pump has an efficiency of 80%. Calculate the kW power needed for the pump. Calculate the total friction losses in kJ/kg.
Chapter 10 Solutions
Applied Fluid Mechanics (7th Edition)
Ch. 10 - Determine the energy loss due to a sudden...Ch. 10 - Determine the energy loss due to a sudden...Ch. 10 - Determine the energy loss due to a sudden...Ch. 10 - Determine the pressure difference between two...Ch. 10 - Determine the pressure difference for the...Ch. 10 - Determine the energy loss due to a gradual...Ch. 10 - Determine the energy loss for the conditions in...Ch. 10 - Compute the energy loss for gradual enlargements...Ch. 10 - Plot a graph of energy loss versus cone angle for...Ch. 10 - For the data in Problem 10.8, compute the length...
Ch. 10 - Add the energy loss due to friction from Problem...Ch. 10 - Another term for an enlargement is a diffuser. A...Ch. 10 - Compute the resulting pressure after a "real"...Ch. 10 - Compute the resulting pressure after a "real"...Ch. 10 - Determine the energy loss when 0.04m3/s of water...Ch. 10 - Determine the energy loss when 1.50ft3/s of water...Ch. 10 - Determine the energy loss when oil with a specific...Ch. 10 - For the conditions in Problem 10.17, if the...Ch. 10 - True or false: For a sudden contraction with a...Ch. 10 - Determine the energy loss for a sudden contraction...Ch. 10 - Determine the energy loss for a gradual...Ch. 10 - Determine the energy lass for a sudden contraction...Ch. 10 - Determine the energy loss for a gradual...Ch. 10 - For the data in Problem 10.22, compute the energy...Ch. 10 - For each contraction described in Problems 10.22...Ch. 10 - Note in Figs. 10.10 and 10.11 that the minimum...Ch. 10 - If the contraction from a 6-in to a 3-in ductile...Ch. 10 - Compute the energy loss that would occur as 50...Ch. 10 - Determine the energy loss that will occur if water...Ch. 10 - Determine the equivalent length in meters of pipe...Ch. 10 - Repeat Problem 10.30 for a fully open gate valve.Ch. 10 - Calculate the resistance coefficient K for a...Ch. 10 - Calculate the pressure difference across a fully...Ch. 10 - Determine the pressure drop across a 90 C standard...Ch. 10 - Prob. 10.35PPCh. 10 - Repeat Problem 10.34 for a long radius elbow....Ch. 10 - A simple heat exchanger is made by installing a...Ch. 10 - A proposed alternate form for the heat exchanger...Ch. 10 - A piping system for a pump contains a tee, as...Ch. 10 - A piping system for supplying heavy fuel oil at 25...Ch. 10 - A 25 mm ODx2.0 mm wall copper tube supplies hot...Ch. 10 - Specify the radius in mm to the centerline of a 90...Ch. 10 - The inlet and the outlet shown in Fig. 10.36 are...Ch. 10 - Compare the energy losses for the two proposals...Ch. 10 - Determine the energy loss that occurs as 40 L/min...Ch. 10 - Figure 10.38 shows a test setup for determining...Ch. 10 - Compute the energy loss in a 90 bend in a steel...Ch. 10 - Compute the energy loss in a 90 bend in a steel...Ch. 10 - For the data in Problem 10.47, compute the...Ch. 10 - For the data in Problem 10.48, compute the...Ch. 10 - A tube similar to that in Problem 10.47 is being...Ch. 10 - Prob. 10.52PPCh. 10 - Prob. 10.53PPCh. 10 - Prob. 10.54PPCh. 10 - Prob. 10.55PPCh. 10 - Repeat Problem 10.55 for flow rates of 7.5 gal/min...Ch. 10 - Prob. 10.57PPCh. 10 - Prob. 10.58PPCh. 10 - Prob. 10.59PPCh. 10 - Prob. 10.60PPCh. 10 - A 34 plastic ball valve carries 15 gal/min of...Ch. 10 - A 114 plastic butterfly valve carries 60 gal/min...Ch. 10 - A 3 -in plastic butterfly valve carries 300...Ch. 10 - A 10-in plastic butterfly valve carries 5000...Ch. 10 - A 1 12 plastic diaphragm valve carries 60 gal/min...Ch. 10 - Prob. 10.66PPCh. 10 - Prob. 10.67PPCh. 10 - Prob. 10.68PPCh. 10 - Prob. 10.69PPCh. 10 - An 8 -in plastic swing check valve carries 3500...Ch. 10 - Use PIPE-FLO software to determine the pressure...Ch. 10 - Use PIPE-FLO to calculate the head loss and...
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Calculate the resistance coefficient K for a check valve swing type placed in a 6 inch schedule 40 steel pipe if water at 100º F flowing with a velocity of 10 ft/sarrow_forwardSaturated water at 310K is being pumped from a tank to an elevated tank at the rate of 7L/s. All of the piping is in 5-in. schedule 40 steel pipe. If the 2 fittings used is 90° ell standard long radius, The pump has an efficiency of 80%. Calculate the total friction losses in kJ/kg.arrow_forward4. A special oil is to be used in an absorption tower. The preliminary design of the unit requires the oil to be pumped from an open tank with a 10 ft liquid level above the floor and forced through 150 ft of 3 inches schedule 40 pipe with a ball check valve and 5 elbows into the top of a tower 30 ft above the floor. The operating pressure in the tower is to be 52 psig and the oil requirement is estimated at 50 gpm. The viscosity of the oil 15 cP and its density is 53.5 Ibm/ft. Assuming the pumping outfit operates with an overall efficiency of 60%, what horsepower input will be required for the pump motor?arrow_forward
- Saturated water at 310K is being pumped from a tank to an elevated tank at the rate of 7L/s. All of the piping is in 5-in. schedule 40 steel pipe. If the 2 fittings used is 90° ell standard long radius, The pump has an efficiency of 80%. Calculate the kW power needed for the pump.arrow_forwardPure milk at 293 K has a density of 1030 kg / m3 and a viscosity of 2.12 cp flowing at a rate of 2,605 kg / s in a pipe having a diameter of 100 mm. a. Calculate the Reynolds number. = Answer . b. Is the flow turbulent No, yes . c. The flow rate required for Reynold's number 2100 is = Answer m / s.arrow_forwardPlease compute the Reynolds number of an oil (0.8 specific gravity, 0.8 cp viscosity) flowing in a pipe of 1- inch diameter at a velocity of 6 ft/s. Is this flow laminar or turbulent?arrow_forward
- 10.4 Determine the pressure difference between two points on either side of a sudden enlargement from a tube with a 2-in ID to one with a 6-in ID when the velocity of flow of water is 4 ft/s in the smaller tube. 10.5 Determine the pressure difference for the conditions in Problem 10.4 if the enlargement is gradual with a cone angle of 15. Answer: p1-p2= -0.0891 psiarrow_forwardCompute the resulting pressure in kPa after a "real" diffuser in which the energy loss due to sudden enlargement is considered for the flow of water at 25°C from a 36 mm OD x 2.0 mm wall copper tube to an 85 mm OD x 2.5 mm wall copper tube, the pipes are the same elevation. The volume flow rate is 150 L/min and the pressure before the enlargement is 500.062 kPa. NB: OD = Outside Diameter, Wall refers to the pipe’s thickness (t) Hints: Obtain the specific weight of water for the given temperature from Appendix A (Table A.1). Obtain the resistance coefficient (K) for sudden enlargement from Table 10.3B in chapter 10. Instructions: Only express the areas in scientific notation to three decimal places but round off to three decimal places in normal number format where necessary throughout your calculations leading to the final answer and including the final answer for all other computations excluding the area.arrow_forwardFLOW THROUGH PIPELINE PROBLEM Process water is pumped from the main storage tank (A) to process tanks (B) and (C). The pipeline from main storage tank (A) to the centrifugal pump inlet is 3-inch Schedule 40 commercial steel pipe, with an equivalent length of 61 meters. The line from the centrifugal pump discharge to the tee (entry into leg) where the pipeline branches is also 3-inch Schedule 40 pipe, with an equivalent length of 30.5 meters. The pipeline from the tee to process tank (B) is 1.5-inch Schedule 40 pipe, with an equivalent length of 183 meters. The pipeline from the tee to process tank (C) is 2-inch Schedule 40 commercial steel pipe, with an equivalent length of 183 meters. The equivalent lengths as given do not include four (4) gate valves, one (1) between storage tank (A) and the centrifugal pump, one (1) between the centrifugal pump and the tee, and one (1) each at process tanks (B) and (C); and two (2) globe valves (bevel seat), globe valve “X” in line from the tee to…arrow_forward
- A pitot-static tube is used to measure the velocity of water in a pipe. The stagnation pressure head is 10 m and static pressure head is 8 m. Calculate the velocity of flow if the coefficient of pitot tube equal to 0.95arrow_forwardQuestion 8 Calculate the friction factor for atmospheric air at 80°F ( = 0.0735 Ibm/ft³, = 1.24 x 105 Ibm / ft-s ) flowing at a velocity of 68 ft/s in a 2 ft diameter galvanized pipe ( = 0.0005 ft) express answer in 4 decimal placesarrow_forwardA piping system is to be installed at place where the pump will transfer the fluid from tank A to tank B. There are two suggested piping designs available to carry the fluid efficiently. Compute and determine which of the available piping arrangement will experience the less pumping powerwith given flow conditions. Discuss the results. Flow conditions are same for both type of designs and given as: Pipe material: stainless steel Volume flow rate: 40 L/sec Assume the working fluid is water at standard atmosphere temperature and both tanks areopen to atmosphere. Pipe inlet is sharp-edged and bends are sharped without vanes. Elevations are as ?? = ?? ? and ?? = ?? ?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Principles of Heat Transfer (Activate Learning wi...Mechanical EngineeringISBN:9781305387102Author:Kreith, Frank; Manglik, Raj M.Publisher:Cengage Learning