Three non-reactive loads are connected in delta across a three-phase, three-wire 400 V supply in the following way: ⚫10 kW between the red and yellow lines; • 6 kW between the yellow and blue lines; and • 4 kW between the blue and red lines. Two wattmeters are available to measure the total power drawn by the three-phase load. If the current coil of one of the wattmeter (W₁) is connected in the red line, and its voltage coil connected across the red and yellow lines, calculate: i. The power measured by wattmeter, W₁. ii. The power that would be measured by the other wattmeter (W2) if it was correctly connected. iii. The overall power factor of the three-phase load.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.28P: For the system shown in Figure 3.34. draw an impedance diagram in per unit by choosing 100 kVA to be...
icon
Related questions
Question
Three non-reactive loads are connected in delta across a three-phase, three-wire 400
V supply in the following way:
⚫10 kW between the red and yellow lines;
• 6 kW between the yellow and blue lines; and
• 4 kW between the blue and red lines.
Two wattmeters are available to measure the total power drawn by the three-phase
load. If the current coil of one of the wattmeter (W₁) is connected in the red line,
and its voltage coil connected across the red and yellow lines, calculate:
i. The power measured by wattmeter, W₁.
ii.
The power that would be measured by the other wattmeter (W2) if it was
correctly connected.
iii. The overall power factor of the three-phase load.
Transcribed Image Text:Three non-reactive loads are connected in delta across a three-phase, three-wire 400 V supply in the following way: ⚫10 kW between the red and yellow lines; • 6 kW between the yellow and blue lines; and • 4 kW between the blue and red lines. Two wattmeters are available to measure the total power drawn by the three-phase load. If the current coil of one of the wattmeter (W₁) is connected in the red line, and its voltage coil connected across the red and yellow lines, calculate: i. The power measured by wattmeter, W₁. ii. The power that would be measured by the other wattmeter (W2) if it was correctly connected. iii. The overall power factor of the three-phase load.
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning