Hot exhaust gases are used in a finned-tube cross-flow heat exchanger to heat 2.5 kg/s of water from 35 to 85-C. The gases [cp = 1.09 kJ/kg . °C] enter at 200 and leave at 93°C. The overall heat-transfer coefficient is 180 W/m2. C. Calculate the area of the heat exchanger using the LMTD approach.

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter5: Analysis Of Convection Heat Transfer
Section: Chapter Questions
Problem 5.41P
icon
Related questions
Question
Hot exhaust gases are
used in a finned-tube
cross-flow heat exchanger
to heat 2.5 kg/s of water
from 35 to 85-C. The gases
[cp = 1.09 kJ/kg . °C] enter
at 200 and
leave at 93°C. The overall
heat-transfer coefficient is
180 W/m2 • °C. Calculate
the area of the heat
exchanger using the LMTD
approach.
Transcribed Image Text:Hot exhaust gases are used in a finned-tube cross-flow heat exchanger to heat 2.5 kg/s of water from 35 to 85-C. The gases [cp = 1.09 kJ/kg . °C] enter at 200 and leave at 93°C. The overall heat-transfer coefficient is 180 W/m2 • °C. Calculate the area of the heat exchanger using the LMTD approach.
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Heat Exchangers
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning