For the following single line diagram of a three-phase system, a three-phase fault occurs at point P and just before the fault the line voltage is 18 kV at P. Find out the transient fault current in pu and original value at point P. Take, the given kVA and kV of the G1 as the new base. [hint: the transient and sub-transient reactances of the synchronous generators are assumed to be same. But for the motors, assume that the transient one is 1.7 times of the sub-transient reactance.] 20,000 KV A 6.9KV yo00 KVA 5KV '14% G1 Tz 平 33/69 AV 11/33KV 20000 KVA 10% G2 lond 5+j8 2 15070 KVA 12%. 25,000 KVA 6.9KV [AN the mpedarmces are given per- unit values) as orebtraen sien

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.56P: Three single-phase two-winding transformers, each rated 3kVA,220/110volts,60Hz, with a 0.10 per-unit...
icon
Related questions
Question
For the following single line diagram of a three-phase system, a three-phase fault occurs at
point P and just before the fault the line voltage is 18 kV at P. Find out the transient fault
current in pu and original value at point P. Take, the given kVA and kV of the G1 as the
new base.
[hint: the transient and sub-transient reactances of the synchronous generators are assumed
to be same. But for the motors, assume that the transient one is 1.7 times of the sub-transient
reactance.]
20,000 KV A
6.9KV
I5メ
G1
yo00 KVA
14%
5KV
M
Tz
(G2
11/33KV
33/69 AV
lond 5+j8 2
20000KVA
15070 KVA
10%
12%
25,000 KVA
6.9KV
[AH the mpedances are given
per-unit values)
8%
as orebtraen sient
ww
Transcribed Image Text:For the following single line diagram of a three-phase system, a three-phase fault occurs at point P and just before the fault the line voltage is 18 kV at P. Find out the transient fault current in pu and original value at point P. Take, the given kVA and kV of the G1 as the new base. [hint: the transient and sub-transient reactances of the synchronous generators are assumed to be same. But for the motors, assume that the transient one is 1.7 times of the sub-transient reactance.] 20,000 KV A 6.9KV I5メ G1 yo00 KVA 14% 5KV M Tz (G2 11/33KV 33/69 AV lond 5+j8 2 20000KVA 15070 KVA 10% 12% 25,000 KVA 6.9KV [AH the mpedances are given per-unit values) 8% as orebtraen sient ww
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Knowledge Booster
Synchronous Generator
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L