(b) Based on the performance and validation methods, explain the distinctions between the two terms listed below: (i) linearity and coefficient of determination (ii) intra-day and inter-day precision (ii) absolute recovery and relative recovery (iv) limit of detection and limit of quantification (y) selectivity and specificity
Q: Which sentence is false about gravimetric analysis? a. It is used for inorganic b. It is used to…
A: The statement which is false about gravimetric analysis is, Relative precision 3% to 4%
Q: How many replicate measurements are needed to decrease the 95 and 99% confidence limits for the…
A:
Q: already took
A: Dear student this question is related to Mathematical errors in chemistry.
Q: . What is the molar absorptivity when the percent transmittance is 56.2%, the pathlength is 2.00 cm,…
A:
Q: You are asked to do quality control and quality assurance during the determination of lead…
A: The limit of quantitation is given by the expression: Limit of quantitation=10 sm where,…
Q: Briefly explain why internal standardization method is useful in analytical chemistry?
A: Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: Indicate which other analytical techniques TGA can be coupled with and what would be the advantages?
A:
Q: Please draw a calibration curve from these numbers and get the epselon(molar absorptivity) and…
A: The concentration v/s absorbance data given is,
Q: Which of the following best describes the application of flow analysis? O a Asample is injected into…
A: The flow injection method was developed by Ruzicka and Hansen in Denmark in the mid-1970. This is a…
Q: A potassium hydrogen phthalate solution was prepared by adding 0.0996 g of dry potassium hydrogen…
A: Here given that, Mass of dry potassium hydrogen phthalate = 0.0996 g So number of mols of…
Q: Quantitative Analysis by External Standard Method Calcium in a juice sample is determined by atomic…
A: Initial concentration of solution = M1 Volume of starting solution used = V1 Concentration of…
Q: To determine the instrument detection limit of Pb2+ ions, a student made 10 blank solutions and…
A: Given: Standard deviation of the signal = 0.199 Equation of the curve =, y = 3.413x + b From here…
Q: What part fo chromatography is being descibe by the following?…
A: These all are the terms used in the chromatography.
Q: The column was packed with 12 g of alumina. A 50:50 mixture of ferrocene and acetylferrocene was…
A: The experiment is about analyzing a mixture of ferrocene and acetylferrocene, quantitatively.
Q: To determine the instrument detection limit of Pb2+ ions, a student made 10 blank solutions and…
A:
Q: What is the actual or real-life application of electrogravimetric analysis? Include the specific…
A: Answer - Electrogravimetric analysis - Electrogravimetry is a method used to separate and quantify…
Q: Write the names of four main GC detectors (titles only). Which one of these detectors is used on its…
A: A question about GC detector, which is to be accomplished.
Q: You are developing a procedure for determining traces of copper materials using a wet digestion…
A:
Q: The column was packed with 12 g of alumina. A 50:50 mixture of ferrocene and acetylferrocene was…
A: Total mass of the mixture of (ferrocene + acetylferrocene) = 0.102 g
Q: In the technique of high performance liquid chromatography (HPLC) the peak area response for a…
A: As per the guideline, since you have asked multiple question, we have solved the first question for…
Q: Which of the following would result in an increase in the calculated ngas 10, assuming the rest of…
A: Number of moles is defined as the mass of the compound divided by the molar mass of the compound.
Q: Describe the following properties of chromatogram (including formula if applicable): Bandwidth…
A: 1.Bandwidth sets the frequency around the wavelength provided by the detector to view and report…
Q: State why calibrators and control for spectophotometry should be purchased in addition to the…
A: Interpretation - To state why calibrators and control for the spectrophotometry should be purchased…
Q: Fluoride determination can be performed photometrically with alizarin red and Zirconium acid…
A: A question based on Beer-Lambert law, which is to be accomplished.
Q: Using the absorbance of [FeSCN]+2 at the wavelength of maximum absorption which you obtained in part…
A: Interpretation: To find the value of molar extinction coefficient at maximum absorption. Given Data:…
Q: |Analyte may be lost at the ashing stage volatile hydride generated by the reaction that occurs is…
A: GFAAS (Graphite furnace atomic absorption spectroscopy) is a thermal technique so, analyte may be…
Q: The detecton limits reported for Al with ICP-AES and GF-AAS are 2 ppb and 5 picograms, respectivly.…
A: Given:Al with ICP-AES = 2 ppb = 2 µg/L = 2×10-6 g/L.Mass of Al with GF-AAS = 5 picogram = 5×10-12…
Q: A 10.00 g sample containing an analyte was transferred to a 250 mL volumetric flask and diluted to…
A: Given, sample is 10 g which is transferred to 250 ml volumetric flask. The first signal after…
Q: To identify the amount of caffeine in my coffee using an HPLC instrument, standard solutions of…
A: We are given the signal versus concentration data for standard solutions. So first we have to plot…
Q: Which statements are TRUE regarding internal standards? I. The response factor is calculated by…
A: Only the statement III is incorrect because the detector response is proportional to their…
Q: (b) Based on the performance and validation methods, explain the distinctions between the two tems…
A: ANSWER (b) (i) Linearity , is the property of a mathematical relationship (function) that can be…
Q: Internal standard (As , Cs ), analyte with known concentration (Ax , Cx ) In a chromatographic…
A: Formula used: Area of analyte signalConc of analyte= F×Area of standard signalConc of…
Q: A graphite furnace atomic absorption spectrophotometer (AAS) was used to determine the arsenic (As)…
A: Concentration of As Absorbance 2 0.17 4 0.28 6 0.48 8 0.53 10 0.72
Q: PerkinElmer Spectrum Version 10.03.09 Wednesday, November 20, 2019815 AM Analyst Student Date…
A: Some important peaks are discussed below A. Broad peak around 3200-3500 cm^-1 corresponding to the…
Q: Briefly explain method validation in analytical chemistry? Discuss typical validation…
A: Answer - Analytical chemistry - Analytical chemistry is the science of obtaining, processing, and…
Q: Identify the components in the single-beam spectrophotometer schematic. Then, match the…
A:
Q: Comment on the strengths and limitations of particle sizing using sieve analysis. Suggest an…
A: Sieving is a technique for particle sizing which is performed to separate a sample based on its…
Q: 1- Calculate the standard deviation of this group. 2- Calculate the Coefficient of variation.…
A: Standard Deviation and Coefficient of variation can be formulated as :
Q: A quality control (QC) sample was run in replicates of six to produce the following concentrations…
A: Answer to ist question: 3.3% Yes
Q: it has been noticed that adulteration of palmoil with carcinogenic dyes is on high.use the knowledge…
A: The adulteration of palm oil with many fat soluble azo dyes that are difficult to separate from the…
Q: (b) Based on the performance and validation methods, explain the distinctions between the two terms…
A:
Q: The data in the following table were extracted from a gas chromatographic analysis of a two-…
A:
Q: You are developing a procedure for determining traces of copper in biological materials using a wet…
A: To calculate the 95% confidence level for the above sample. Confidence interval = X ±ZσnX = mean…
Q: Which of the following is TRUE regarding instrumental methods of analysis? A. these methods have…
A:
Q: A 0.500g sample is analyzed spectrophotometrically for manganese by dissolving it in acid and…
A: Given the mass of impure manganese(Mn) sample = 0.500 g 1st dilution: First, the solution was…
Q: FT-IR technique can be utilized for the analysis of unknown analytes by matching it with__________.…
A:
Q: A spectrophotometric method for the quantitative analysis of Pb2+ in blood has a normal calibration…
A: Given that the normal calibration equation is Sstd = (0.296 ppb-1) Cstd+0.003.
Kindly answer this question iii, iv & v
Step by step
Solved in 2 steps
- Atomic Spectroscopy (a) In terms of spectral shape, how are atomic spectra different from molecular spectra? What is the source of this difference? (b) Describe the decision-making process for picking a line for atomic emission analysis of a given analyte. (c) For quality assurance, spike recovery is not sufficient to establish confidence in an analytical procedure. Explain this statement. What should be done instead to demonstrate satisfactory performance of an instrumental method (including elemental analysis). (d) Find a literature example of atomic spectroscopy used for elemental analysis. State the operating conditions with sufficient detail to reproduce the analysis; Please answer very soon will give rating surely All questions complete Answer needed Please help me(b) Based on the perfomance and validation methods, explain the distinctions between the two tems listed below: (1) linearity and coefficient of detemination (ii) intra-day and inter-day precision (ii) absolute recovery and relative recovery (iv) limit of detection and limit of quantification (v) selectivity and specificityAn atomic absorption method for the determination of the amount of iron present in used jet engine oil was found from pooling 30 triplicate analyses to have a standard deviation s = 3.1 µg Fe/mL. If s is a good estimate of o, calculate the 95 and 99% confidence intervals for the result 21.7 µg Fe/mL if it was based on the following criteria. (a) a single analysis 95% confidence interval= 21.7 + 99% confidence interval = 21.7 + (b) the mean of two analyses 95% confidence interval = 21.7 + 99% confidence interval= (c) the mean of six analyses 21.7 ± 95% confidence interval = 21.7 + 99% confidence interval= 21.7 + μg Fe/mL μg Fe/mL μg Fe/mL μg Fe/mL μg Fe/mL μg Fe/mL
- (2) A CHEM 215 student performed 5 measurements of the wt% of SO4²- of a solid power sample. The results are 8.75%, 8.85%, 8.89%, 8.71%, 8.64%. The standard deviation is 0.10%. What is the confidence interval for this student's experiment at 95% confidence level. The t values for 95% confidence for degree of freedom from 1 to 5 are 12.71, 4.303, 3.182, 2.776, 2.571, respectively. Show your work!A solution was prepared from an amount n = (0.500 ± 0.005) mol dissolved in a volume V = (250.0 ± 0.5) cm3. What is the absolute uncertainty in the concentration in units of mol dm-3?(a) You measure the percent transmittance of a solution containing chromophore X at 400nm in a 1-cm path length cuvette and find it to be 50%. What is the absorbance of this solution? (b) What is the molar absorptivity of chromophore X if the concentration of X in the solution measured in question (a) is 0.5mM? (c) What is the concentration range of chromophore X that can be assayed if, when using a sample cell of path length 1, you are required to keep the aborbance between 0.2 and 0.8?
- The Na* concentration in a blood serum sample was determined using the method of standard addition and atomic spectroscopy. 25.00 mL aliquots of serum were pipetted into five 50.00 mL volumetric flasks into which 2.640 M NaCl standard was added as shown in the table below. After dilution to volume, the emission of each solution was measured and used to plot a calibration graph. Flask 1 23 4 5 Vol. of standard (mL) 0 1.00 2.00 3.00 4.00 Emission signal 3.13 5.40 7.89 10.30 12.48 Analytical signal (emission) 14 42 10 12 4 2 0 0 0.05 y = 44.697x + 3.12 R² = 0.9995 0.1 0.15 Concentration of added analyte (M) 0.2 a) Using the plotted calibration graph, calculate the Na* concentration in the blood serum sample. b) Provide a possible reason why the serum sample might have been analysed using this analytical procedure. 0.25In the analysis conducted with flame AAS, standard solutions of the X-type are analyzed individually and the absorbance values obtained are plotted against concentration (ppm). It was seen that the slope of the calibration line obtained was 0.0925. The standard deviation of the absorbance values obtained by reading the blank 10 times under the same conditions was calculated as 0.00183 ppm. According to this; For the X-type calculate the following: a) LOD b) LOQ c) SensitivityAn atomic absorption method for the determination of the amount of iron present in used jet engine oil was found from pooling 30 triplicate analyses to have a standard deviation s = 3.6 mg Fe/mL. If s is a good estimate of σ, calculate the 95 and 99% confidence intervals for the result 18.5 mg Fe/mL if it was based on (a) a single analysis, (b) the mean of two analyses, and (c) the mean of four analyses.
- Quantitative Analysis by External Standard Method Calcium in a juice sample is determined by atomic absorption spectrophotometry. A stock solution of calcium is prepared by dissolving 1.834 g of CaCl, 2H20 in water and diluting to 1000.0 mL. A substock calcium solution was prepared by transferring 10.00 mL of the stock to a 100.00 mL volumetric flask and diluting to the mark. Three standard solutions of calcium were prepared by transferring 2.500 mL. 5.00 mL and 10.00 mL of substock to 50.00 mL volumetric flasks and diluting to the mark. The sample is prepared by transferring 1.000 mL of fruit juice from the original bottle to a 25.00 mL flask and diluting to the mark. Strontium chloride is added to all solutions before dilution to avoid phosphate interference. Instrumental response of the standards is measured against the blank, and the following readings are recorded: 9.10, 18.6 and 37.0. The sampie reading is 28.1. Using the multipoint method, find the concentration of calcium in…A 10.00 g sample containing an analyte was transferred to a 250 mL volumetric flask and diluted to volume. When a 10.00 mL aliquot of the resulting solution was diluted to 25.00 mL it was found to give a signal of 0.235 (arbitrary units). A second 10.00 mL aliquot was spiked with 10.00 mL of a 1.00 ppm standard solution of the analyte and diluted to 25.00 mL. The signal for the spiked sample was found to be 0.502. Calculate the weight percent of analyte in the original sample.2 (1) When performing chemical measurements, replicate experiments are often needed. This is to mitigate (Systematic or Random) error. (2) A CHEM 215 student performed 5 measurements of the wt% of SO4²- of a solid power sample. The results are 8.75%, 8.85%, 8.89%, 8.71%, 8.64%. The standard deviation is 0.10%. What is the confidence interval for this student's experiment at 95% confidence level. The t values for 95% confidence for degree of freedom from 1 to 5 are 12.71, 4.303, 3.182, 2.776, 2.571, respectively. Show your work!