A single-phase, 2,959 VA, 2200/220 transformer has the following open circuit and short circuit test data: Open-circuit test: 433 watts, while the test is carried out at rated voltage. Short circuit test: 434 watt, while the test is carried out at rated current. for a unity power factor, calculate the PERCENT transformer efficiency at 2% of the rated load

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.9P
icon
Related questions
Question

Please answer all subparts for like either dislike is ready. 

Thanks 

A single-phase, 2,959 VA, 2200/220 transformer has the following open circuit and short circuit test data:
Open-circuit test: 433 watts, while the test is carried out at rated voltage.
Short circuit test: 434 watt, while the test is carried out at rated current.
for a unity power factor, calculate the PERCENT transformer efficiency at 2% of the rated load
Question 6
A 3-phase, 230 V, 30 KVA, 0.9 PF(lag) load is supplied by three 10 KVA, 1330/230 V, and 60 Hz transformers
connected in YA. The transformers are supplied from a 3p source through a 3p feeder whose impedance is
3+14 2 per phase. The equivalent impedance of one transformer referred to on the low-voltage side is
0.3+j0.3 02. Determine:
The supply voltage if the load voltage is 230 V.
The % voltage regulation
Transcribed Image Text:A single-phase, 2,959 VA, 2200/220 transformer has the following open circuit and short circuit test data: Open-circuit test: 433 watts, while the test is carried out at rated voltage. Short circuit test: 434 watt, while the test is carried out at rated current. for a unity power factor, calculate the PERCENT transformer efficiency at 2% of the rated load Question 6 A 3-phase, 230 V, 30 KVA, 0.9 PF(lag) load is supplied by three 10 KVA, 1330/230 V, and 60 Hz transformers connected in YA. The transformers are supplied from a 3p source through a 3p feeder whose impedance is 3+14 2 per phase. The equivalent impedance of one transformer referred to on the low-voltage side is 0.3+j0.3 02. Determine: The supply voltage if the load voltage is 230 V. The % voltage regulation
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Infinite Impulse Response (IIR) and Finite Impulse Response (FIR) Filter
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning