2 (a) Why the primary winding of the distribution transformer used in electrical installation in building is always connected in Delta, while the secondary is always connected in Wye!

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
Question
2
(a)
Why the primary winding of the distribution transformer used in electrical installation in
building is always connected in Delta, while the secondary is always connected in Wye!
(b)
A wye-connected three-phase generator supplies power to a delta-connected resistive
load (see the Figure Q2). Each impedance load of the delta connected load equals Zas
given bellow.
Alternator
Ep
Ip
EP
Ip
EL
EL
IL
j42
Figure 02
Find the following values:
EPLoad)- phase voltage of the load
IpLoad)- phase current of the load
Inoad)- line current to the load
ILAR)- line current delivered by the alternator
IPIAK)- phase current of the alternator
EPIAN) - phase voltage of the alternator
P - true power consumed by the load if the load is purely resistive with
resistance of 32
Transcribed Image Text:2 (a) Why the primary winding of the distribution transformer used in electrical installation in building is always connected in Delta, while the secondary is always connected in Wye! (b) A wye-connected three-phase generator supplies power to a delta-connected resistive load (see the Figure Q2). Each impedance load of the delta connected load equals Zas given bellow. Alternator Ep Ip EP Ip EL EL IL j42 Figure 02 Find the following values: EPLoad)- phase voltage of the load IpLoad)- phase current of the load Inoad)- line current to the load ILAR)- line current delivered by the alternator IPIAK)- phase current of the alternator EPIAN) - phase voltage of the alternator P - true power consumed by the load if the load is purely resistive with resistance of 32
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning