type sensor includes SnO2 layer which changes its resistance with respect to reducing gas concentration. None MOS Infra-red Catalytic Electro-chemical
Q: sely proportional to the column efficiency irectly proportional to the selectivity factor not…
A: B option is correct. Inversely proportional to column efficiency. Band-broadening is a general term…
Q: How do you measure quinine sulphate concentration using fluorescence method? What is the one…
A: In this question, we have to determine : (a) steps for measurement of quinine sulphate concentration…
Q: 7.If C% increase the T.S. and hardness is . 8. Surface treatment by atmosphere of ammonia and…
A: 7. If C% increases the T.S and hardness is higher 8. Surface treatment by atmosphere of ammonia and…
Q: onsider liquid n - hexane in a 50 - mm - diameter graduated cylinder. The distance from the liquid -…
A: The given cylinder diameter = 50 mm Distance between Liquid –gas interface Given is 200 m .n- hexane…
Q: Cyclic Voltammogram of 10mM Ruthenium Hexamine 40 20 -20 -40 -60 -0.4 -0.2 0.0 0.2 potential (V) The…
A:
Q: t is a good practice when leaving an operating equipment unattended? Record the equipment using a…
A: When we have to leave and the equipment is already operating then we should do following thing.
Q: this initiates by converting mercury into Hg2+ by oxidation from nitric and sulfuric acids, followed…
A: GFAAS is graphite furnace atomic absorption spectroscopy. It is widely used to determine trace…
Q: A student recorded the following end-point volumes in a redox determination of ferrous iron against…
A: Here we are required to find standard deviation for the end point volume used during redox titration…
Q: How much more air conditioning supply air will be needed in a room with a 50 sq ft single strength,…
A: Solar heat gains factor (SHGF) and shading constant are the quantities used to calculate shaded…
Q: The thermal conductivity detector operates by measuring the of a hot filament that is the result of…
A: THERMAL CONDUCTIVITY DETECTOR A thermal conductivity detector is used to calculate the thermal…
Q: There is a series type ohmmeter, designed to operate on a 6 V battery. The galvanometer has an…
A:
Q: Sketch the power density distribution for oxyfuel gas welding and GMAW process.
A: Oxy-fuel welding and oxy-fuel cutting are processes that use fuel gases and oxygen to weld or cut…
Q: A sheet of steel 1.5 mm thick has nitrogen atmospheres on both sides at 1200°C and is per- mitted to…
A: Since you have asked multiple questions questions, we will solve the first question for you. If you…
Q: Briefly compare and contrast flash-photolysis with shock-tube method.
A: Flash-photolysis and shock-tube method are used to study kinetics of fast reactions.
Q: Determine the lifetime of NO2 at night against the reaction NO2 + O3 → NO3 + 02 at z = 0, 5, and 10…
A:
Q: Q3\\ Nickel bis-dimethylglyoximate complex was deposited with a weight of (2.721g) with the filter…
A: % Ni+2 in complex = ? We have given the mass of sample + filter paper = 2.721 g
Q: Why is better sensitivity usually achieved using graphite furnace atomizatiorrather than flame…
A: Flame atomization: Flame atomization is an atomic absorption spectroscopic analytical technique that…
Q: The cool plasma tail needs to be removed in regular ICP-OES analysis using the axial view. Provide…
A: A question about spectroscopy, which is to be accomplished.
Q: Nitrogen from a gaseous phase is to be diffused into pure iron at 700°C. If the surface…
A: Introduction: Fick's second law of diffusion states that the rate of accumulation of concentration…
Q: Which of the following is the correct flow of the mobile phase in HPLC? Solvent degasser>Guard…
A: The mobile phase in HPLC is used to transport the sample via seperation column and there by detector…
Q: Overpotential is due to __. Select all that apply. Mass transfer Charge transfer…
A: Mass transfer Charge transfer Is affects the overpotential.
Q: Please help me please. I promise to give a feedback.. I only need the answer of definitions please.…
A: Combustion, is a chemical reaction between a substance and oxygen, usually in the form of a flame,…
Q: A. Oxidant B. Electrode discharge lamp C. Detector D. Discrete atomizer E. Nebulizer atomizer F.…
A: A question based on tools in analytical chemistry that is to be accomplished.
Q: A coal with high ash content is undesirable, as * it is abrasive to the coal pulveriser (ie.g. ball…
A:
Q: Polarographic cells are used to measure the partial pressure of gases only in static gas monitoring…
A: Please see explanation
Q: What type of instrument is shown in the diagram? Reference cell Po 0. Amplifier Grid Source hv…
A: The light beam in single beam instruments passes through the sample without splitting, but the beam…
Q: Yeid stengh (MP Yeld sengh s Tensle stengh MP Tenale stengh a Ducsty NEU Focusing on brass, of the…
A: A question about quantitative analysis, which is to be accomplished.
Q: In a copper lamp used in Flame Atomic Absorption Spectroscipy, the copper metal inisde is the…
A:
Q: 5. A sheet of BcC iron 1 mm thick was exposed to a carburizing gas atmosphere on one side and a…
A:
Q: Nitrogen from a gaseous phase is to be diffused into pure iron at 700°C. If the surface…
A: From Ficks second law of diffusion, we have (Cx - C0) /(Cs - C0) = 1 - erf(x/ 2Dt) -----(i)…
Q: GCMS is running at high temperatures to achieve compounds vaporization and separation. Describe why…
A: Interpretation- To describe why the transfer line temperature and filament are usually set similar…
Q: One litre flask is containing air and acetone at 1 atm and 303 K with a relative humidity of 35% of…
A:
Q: following available on the polarization curve of the active- surface TAEFL alloy M-metal. If Q1/ The…
A: Technique of cathodic protection:- This electrochemical technique is used to to reduce the…
Q: Sketch a graph of the van Deemter equation (plate height versus flow rate). What would the curve…
A: The van Deemter equation is a relationship between the height of the plate during the flow of mobile…
Q: Match the ff. definition/use with the correct detector being described. consists of a…
A: A phototube, makes use of the photoelectric effect, and have semi cylindrical photocathode and wire…
Q: What is the dimension of a chlorine contact chamber if the CT value is 150 mg-min/L at the chlorine…
A: Given: CT value=150 mg-min/L Chlorine concentration=5 mg/L
Q: 5. A sheet of BCC iron 1 mm thick was exposed to a carburizing gas atmosphere on one side and a…
A:
Q: What is the major advantage of Dropping Mercury Electrode (DME)?
A: The major advantages of Dropping Mercury Electrode (DME) are :- i) Mercury form amalgam with most…
Q: application of intergration
A: To determine the rate of a chemical reactions.
Q: n. If a solute is added to a liquid, then the time of complete mixing is infinite no matter how…
A: The following statement are explained below :
Q: Report on the mechanism of action of the thermocouple
A: A thermocouple is a type of a sensor which is used to determine the temperature of a system at a…
Q: Define cyclic voltammetry. Label the following numbers (1, 2, 3 and 4) given below in cyclic…
A: cyclic voltammetry is an electrochemical technique for measuring the current response of a redox…
Q: ime of Time at dicator color equivalence point, s ange, s
A: Molecular equation, HCl(aq.) + NH3(aq.) ---> NH4Cl(aq.) Complete ionic equation, H+(aq.) +…
Q: A disk type centrifuge with disks at 450 angle is used to clarify a suspension of E.coli cells with…
A: Centrifugation is a mechanical process which involves use of centrifugal force to separate particles…
Q: Given the volume of 0.2000 M NAOH used determine the concentration of 10.00 ml sample each from…
A: Given, Volume of NaOH for Aq layer = 12.55 mL Volume of NaOH for Or layer = 15.27 mL Concentration…
Q: 14- The coefficient of thermal expansion and API have an inverse relationship true False
A: True
Q: State the general idea behind electrogravimetric analysis.
A: Gravimetry is an analytical method to determine an unknown compound on the basis of mass. In this…
Q: 1- A silicon wafer with crystal orientation was placed at an oxidation furnace for one hour.…
A:
![type sensor includes SnO2 layer which changes its resistance with respect
to reducing gas concentration.
None
MOS
Infra-red
Catalytic
Electro-chemical](/v2/_next/image?url=https%3A%2F%2Fcontent.bartleby.com%2Fqna-images%2Fquestion%2F3a1fbfdb-9128-4f36-b010-0e3466525ebb%2F31d5de43-c970-4884-8de6-f82c455fe6e8%2Fubkrtnv_processed.jpeg&w=3840&q=75)
![](/static/compass_v2/shared-icons/check-mark.png)
Step by step
Solved in 2 steps with 1 images
![Blurred answer](/static/compass_v2/solution-images/blurred-answer.jpg)
- Read the excerpts from chemistry journal articles. Determine which section each quote was likely derived from, then label the quote accordingly. "A total of 18 GFRP-SR confined concrete cylinders with a diameter of 150 mm Discussion and a height of 300 mm were constructed and tested under axial compression." "Since Alfred Loomis's studies in the 1920's, ultrasonic waves of various frequencies have found uses in areas such as medical imaging, geological imaging Introduction (SONAR), industrial cleaning and welding, solution mixing, and even jewelry cleaning." %3D "The thermogram of the pure NIA revealed a sharp endothermic signal with maximum Experimental at 204.75 °C, and AH = 30.54 kJ/mol, that corresponds with the melting of the NIA." "As we have demonstrated here that a pulse of blue light 450–475 nm, the simulating wavelength of melanopsins and/or cryptochromes, increases the expression of Per1 Results and Per2, one of these photopigments is most probably responsible for light…Readion Cone, Nay S0, Cine HCI|Ab. 1 | Rabe I1.3085840 65.56796607 Cone, Nagd, 03 ATme (5) 0.10 M ·30M 04563164 |0.028 F09 13 ,15 M 12267196|0.01870913 30M |1.5360817 0.300349 O.10 M 3 0.050 M 5. 11431671 4 0.025 M 0:30M 1.3686611 1,358380874 1.007568 3. What is the overall order of the reaction? Write the complete rate law for this reaction.If a gas A is adsorbed on a solid surface .12 and obeys Langmuir Isotherm model. The plotting of V/P versus P yields a linear relationship with slope 0.56 and Intercept = 1.15, then the V, "the volume corresponding to complete coverage" and K "Equilibrium constant for adsorption process", * :respectively are %3D 2.054 ,1.786 0.487,1.786 0.487,0.870 0.565,1.538 0.430 ,1.538
- ) - O + 88 www-awu.aleks.com Files Lecture 16 - The Punic... Rhetorical Analysis Essa... Journal Assignment: Pre... Document3.docx ALEKS - Anniston Stovall... b Answered: One way the... O CHEMICAL REACTIONS Anniston V Solving for a reactant in solution 1/5 One way in which the useful metal copper is produced is by dissolving the mineral azurite, which contains copper(II) carbonate, in concentrated sulfuric acid. The sulfuric acid reacts with the copper(II) carbonate to produce a blue solution of copper(II) sulfate. Scrap iron is then added to this solution, and pure copper metal precipitates out because of the following chemical reaction: Fe(s) + CUSO 4(aq) Cu(s) + FeSO4(aq) Suppose an industrial quality-control chemist analyzes a sample from a copper processing plant in the following way. He adds powdered iron to a 100. mL copper(II) sulfate sample from the plant until no more copper will precipitate. He then washes, dries, and weighs the precipitate, and finds that it has a mass of…A student obtained an average PV value of 42,000 in column ( of the data table. If the syringe had een able to be adjusted to a volume of 35.0 mL, what would the pressure be inside the flask? emember that PV = k and the volume you used includes the flask as well as the syringe. Given that the volume of the flask and the syringe is 553. Round to the correct sig figs.Analyte may be lost at the ashing stage volatile hydride generated by the reaction that occurs is swept into the atomization chamber by an inert gas, where it undergoes decomposition. detection limits by a factor of 10 to 100 compared to alternative methods v limited to only the determination of mercury.
- Consider the plot of Ecell vs. pPb in the potentiometric analysis of Pb2+, the Nernstian slope is a) 29.6 mV b) -29.6 mV c) 59.2 mV d) -59.2 mVWrite the differences between physisorption and chemisorption with respect to the following: (i) Specificity (ii) Temperature dependence (iii) Reversibility and (iv) Enthalpy changeWhat arc the advantages of microfabricated ISEs? Describe typical applications of this type of sensor.
- In a study of the gas phase decomposition of dinitrogen pentoxide at 335 K N,O;(g2 NO,(g) + % O2(g) the concentration of N2Og was followed as a function of time. It was found that a graph of In[N2O3] versus time in seconds gave a straight line with a slope of -6.96x10-3 s1 and a y-intercept of -1.41. Based on this plot, the reaction is order in N2Og and the rate constant for the reaction is s-!.Provide the remaining data missing-awu.aleks.com/alekscgi/x/Isl.exe/1o_u-IgNslkr7j8P3jH-IQg34RWYTxj_1SoekWMaP1As1fEhnC179H4SL2ZsgO0wePS_GkvJitHEX1MKthb4VX9coDdX5z6C9y= O ATOMS, IONS AND MOLECULES Naming ionic compounds with common polyatomic ions Fill in the name and empirical formula of each ionic compound that could be formed from the ions in this table: cation 4+ Pb 2+ Fe 2+ Zn anion 103 so² Cro Some ionic compounds empirical formula 0 0 name of compound 0 X
![Principles of Instrumental Analysis](https://www.bartleby.com/isbn_cover_images/9781305577213/9781305577213_smallCoverImage.gif)
![Principles of Instrumental Analysis](https://www.bartleby.com/isbn_cover_images/9781305577213/9781305577213_smallCoverImage.gif)