The short current in the short circuit test for the single phase transformer is----- *
Q: In a single phase transformer, what test to be conducted to measure the iron losses directly .…
A: In the question Draw the single phase diagram to measure iron losses. Which method is used to…
Q: Berry type transformer has has more than two magnetic circuits. Select one: O True False
A:
Q: TRUE or FALSE: You can remove one transformer in a three-phase transformer bank connected in…
A: The correct option is true. if you remove one Transformer in a three phase transformer Bank…
Q: Primary of Current Transformer is having large number of turns. Select one: True O False
A: The current ratio will sets the turns ratio and as the primary usually consists of one or two turns…
Q: A single phase transformer has a full load total loss of 900 W and an iron loss of 500 W. The copper…
A: A transformer is an electrical machine which is used in AC circuit to either step up or step down…
Q: Two single-phase transformers having equal turns ratio supply, in parallel a secondary load of 750 A…
A:
Q: In step up transformer, number of turns in secondary is higher than primary. Select one: True False
A:
Q: A step-down transformer is one at which the secondary voltage is higher than the primary voltage.…
A: Tranformer is a constant frequency and constant power device . transformer consists of two windings…
Q: A three-phase transformer, connected in star-delta, is composed of three single-phase transformers,…
A: Given, A 3-phase transformer, connected in star-delta, is composed of 3 single phase transformers,…
Q: If the core loss of single phase transformer at full load is 294 W, then the core loss at 50% of…
A: In this question we need to find a core loss of a transformer at 50% load
Q: A 50 kVa single phase transformer has an initial cost of P120,000 and a salvage value of P35,000…
A: Here, we have given a 50 kVA single phase transformer: having the initial cost of P120,000. the…
Q: 1. What happen when the two transformers are operated in parallel having un equal turn's ratio. 2.…
A: 1: If two transformers with different transformation ratios (un-equal turn's ratio) are connected in…
Q: In load test on single phase transformer, the secondary voltage increases with decrease in load.…
A: Ans. True
Q: The line to ground voltages on the high voltage side of a step-up transformer are 100 kV, 33 kV and…
A: resolving the unbalanced three-phase system in terms of symmetrical components, it can be…
Q: The choice of protection scheme for transformer depends on its. Power capacity Type of cooling…
A: Transformer is device which needs to be protected form the various king of faults. and different…
Q: The line to ground voltage on the high voltage side of a step-up transformer are 100 kV, 33 kV, 38…
A: Given that A Phase voltage is 100 kV. B Phase voltage is 33 kV. C Phase voltage is 38 kV. The…
Q: Auto transformer windings are wound on two separate limbs of the iron core True False 00
A: The explanation is as follows.
Q: In transformer, which is always working with its secondary short circuited.
A: In the question, fill the blank In......... Transformer, which is always working with it's…
Q: If the core loss of single phase transformer at full load is 284 W, then the core loss at 25% of…
A: Core losses at full load = 284W. Find the core losses at 25% load?
Q: If the core loss of single phase transformer at full load is 316 W, then the core loss at 50% of…
A: If the core losses of single phase transform at full load = 316W Find the losses at 50% load?
Q: In a 1-phase transformer, if the no load secondary terminal voltage is 222 V and the full load…
A: Given that Vnl=222VVfl=209V
Q: What happen when the two transformers are operated in parallel having un equal turn’s ratio.
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: transformer, the secondary side operates almost in open circuited condition.
A:
Q: In a single phase transformer, when no-load voltage is 230V and full load terminal voltage is 220,…
A:
Q: Write ‘T’ for True and ‘F’ for False The phase shift angle of a Δ-Y transformer can only be 30⁰
A: In this question we will find phase shift between delta star transformer..
Q: 13) Primary of Current Transformer is having less number of turns. Select one: True False
A: Current transformer- A current transformer is used the extending the range of the ammeter and also…
Q: For a 250 [kVA] practical transformer with 4160 [V) primary and 480 [V] secondary, the base…
A:
Q: the core loss of single phase transformer at full O 52W O 105W O 13W O 210W
A: In transformer, mainly two losses present namely core and copper losses.
Q: 4. A 220-kVA transformer with .2% resistance and 4% reactance and another 120-kVA transformer with…
A:
Q: What is the influence of transformer in single-phase connections transformers phase operation…
A: Types of primary and secondary coil connections Star Star Star delta Delta delta Delta star…
Q: A transformer with a single winding serving as primary and secondary
A: TRansformer: It is a static device that is used to transfer electric energy at a constant frequency…
Q: At 50Hz operation a single phase transformer has eddy current loss of 100 W, Its eddy current loss…
A:
Q: The purpose of Scott connection of transformer is to convert...
A: Need to explain purpose of Scott connection of transformer is to convert
Q: In a 1-phase transformer, if the no load secondary terminal voltage is 227 V and the full load…
A: Although formula for voltage regulation is given by %VR=Vno load-Vfull loadVno load×100% Given…
Q: if the core loss of 1 phase transformer at full load is 124 W, then the core loss at 50% of load is…
A: The core loss of 1 phase transformer at full load is 124 W P = 124 W Note : Since the core…
Q: Answer by true or false True False The core type of single phase transformer has a double magnetic…
A: A core type single phase transformer is shown in figure below: In the above there is only one core…
Q: In transformer , which is always working with its secondary short circuited.
A: In this question , we have to find out transformer in which secondary short circuited...
Q: In step down transformer, number of turns in primary is higher than secondary. Select one: True…
A: In this question we need to verify the given statement is true or false
Q: Transformer works on the principle of mutual induction between two circuits True/False A9 linked by…
A: Basically transformer has two windings wound on common core and both winding links same flux.
Q: In a single phase transformer, when no-load voltage is 230V and full load terminal voltage is 220,…
A:
Q: Calculate the percentage regulation of a transformer, if the No load secondary terminal voltage is…
A: Vnl =239 V Vfl = 207 V % R. = ( VNL-VFL) /(VFL) × 100% % R is percentage regulation
Q: If the core loss of single phase transformer at full load is 306 W, then the core loss at 50% of…
A: Given : Here they have mentioned the copper loss of a single phase transformer at the full load…
Q: TRUE or FALSE: Delta-wye configuration of three-phase transformer is best suited for step-up…
A: This question belongs to electrical machine . It is based on the delta star configuration of three…
Q: 4. A 220-kVA transformer with .2% resistance and 4% reactance and another 120-kVA transformer with…
A: In this question we need to find a load share by two transformer
Q: solve with transformators topic With a ratio of turns of 10 to 1 and an input voltage of 120V and…
A: In this question With a ratio of turns of 10 to 1 an input voltage of 120V and output 12 V, What is…
Q: Which of the following is the phase angle error (in degree) for a current transformer of class T…
A: We need to select the appropriate option for the phase angle error for a current transformer of…
Q: Primary of Current Transformer is having few turns. Select one: O True O False
A: Current Transformer is a measuring device. It is used to measure current in a high power conductor…
Q: The percentage impedance of a transformer is 8%. Determine the short-circuit current for a…
A: The per unit short circuit current at a transformer terminal is the inverse of per unit impedance of…
Q: The purpose of the short circuit test of the transformer is to measure the copper losses.…
A: In this question we need to verify the given statement is true or false.
Step by step
Solved in 2 steps with 2 images
- A single-phase step-down transformer is rated 13MVA,66kV/11.5kV. With the 11.5 kV winding short-circuited, rated current flows when the voltage applied to the primary is 5.5 kV. The power input is read as 100 kW. Determine Req1andXeq1 in ohms referred to the high-voltage winding.A single-phase, 50-kVA,2400/240-V,60-Hz distribution transformer has the following parameters: Resistance of the 2400-V winding: R1=0.75 Resistance of the 240-V winding: R2=0.0075 Leakage reactance of the 2400-V winding: X1=1.0 Leakage reactance of the 240-V winding: X2=0.01 Exciting admittance on the 240-V side =0.003j0.02S (a) Draw the equivalent circuit referred to the high-voltage side of the transformer. (b) Draw the equivalent circuit referred to the low-voltage side of the transformer. Show the numerical values of impedances on the equivalent circuits.The symbol shown is a(n) a. iron core transformer. b. auto transformer. c. current transformer. d. air core transformer.
- Rework Problem 3.14 if the transformer is delivering rated load at rated secondary voltage and at (a) unity power factor, (b) 0.8 power factor leading. Compare the results with those of Problem 3.14. -The ratings of a three-phase three-winding transformer are Primary(1): Y connected 66kV,15MVA Secondary (2): Y connected, 13.2kV,10MVA Tertiary (3): A connected, 2.3kV,5MVA Neglecting winding resistances and exciting current, the per-unit leakage reactances are X12=0.08 on a 15-MVA,66-kV base X13=0.10 on a 15-MVA,66-kV base X23=0.09 on a 10-MVA,13.2-kV base (a) Determine the per-unit reactances X1,X2,X3 of the equivalent circuit on a 15-MVA,66-kV base at the primary terminals. (b) Purely resistive loads of 7.5 MW at 13.2 kV and 5 MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per- unit impedance diagram, showing the per-unit impedances on a 15-MVA,66-kV base at the primary terminals.For an ideal transformer, the efficiency is (a) 0 (b) 100 (c) 50
- With the American Standard notation, in either a Y-or-Y transformer, positive- sequen quantities on the high-voltage side shall lead their corresponding quantities on the low-voltage side by 30. (a) True (b) FalseFor an ideal 2-winding transformer, an impedance Z2 connected across winding 2 (secondary) is referred to winding 1 (primary) by multiplying Z2 by (a) The turns ratio (N1/N2) (b) The square of the turns ratio (N1/N2)2 (c) The cubed turns ratio (N1/N2)3Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage windings are connected in Y. (a) For the low-voltage side, connect the windings in , place the polarity marks, and label the terminals a, b, and c in accordance with the American standard. (b) Relabel the terminals a, b, and c such that VAN is 90 out of phase with Va for positive sequence.
- Using the transformer ratings as base quantities. work Problem 3.14 in per-unit.The direct electrical connection of the windings allows transient over voltages to pass through the auto transfonner more easily, and that is an important disadvantage of the autotransformer. (a) True (b) FalseAn ideal transformer has no real or reactive power loss. (a) True (b) False