Q2 (a) A 440 V, six poles, 80 hp, 60 Hz, Y connected three phase induction motor develops its full load induced torque at 3.5 % slip when operating at 60 Hz and 440 V. The per phase circuit model impedances of the motor are R₁ = 0.32 0 XM = 32 Ω X1 = 0.44 Ω Xz = 0.38 Ω Mechanical, core, and stray losses may be neglected in this problem. Find the value of the rotor resistance R₂.
Q2 (a) A 440 V, six poles, 80 hp, 60 Hz, Y connected three phase induction motor develops its full load induced torque at 3.5 % slip when operating at 60 Hz and 440 V. The per phase circuit model impedances of the motor are R₁ = 0.32 0 XM = 32 Ω X1 = 0.44 Ω Xz = 0.38 Ω Mechanical, core, and stray losses may be neglected in this problem. Find the value of the rotor resistance R₂.
Chapter39: Synchronous Motor Operation
Section: Chapter Questions
Problem 14SQ: Induction motors and welding transformers require magnetizing current, which causes a. lagging power...
Related questions
Question
Please send asap...tq
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 3 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning