Q1: Answer by YES or NO for the following sentences: 1- Detectors that are applied to radiation dosimetry are often used in pulse mode. 2- Radiation detectors used for nuclear reactors' power monitoring are most often operated in current mode. 3- Pulse mode detectors measure the average current over many interactions. 4- The amplitude of the signal in the pulse mode is proportional to the charge generated within the detector. 5- The sensitivity in the current mode is many factors greater than when using pulse mode. 6- The information on individual pulse amplitude is lost in the current mode. 7- Peaks in the DPHS indicate pulse amplitude about which few pulses occur. 8- Valleys appear in DPHS means a region of maximum slope observed in the integral distribution. 9- Minimum sensitivity to drifts in discrimination level is achieved at the plateaus of the counting curves. 10- When the value of the resolution decreased, the resolution of the detector decreased too. 11- The statistical noise in the detectors is arising from the drift of operating conditions. 12- In non-paralyzable detectors, the true events which occur during the dead period are assumed to further extend the dead time. 13- Two-source method provides a test for the validity of the assumed dead time model.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Q1: Answer by YES or NO for the following sentences:
1- Detectors that are applied to radiation dosimetry are often used in pulse mode.
2- Radiation detectors used for nuclear reactors' power monitoring are most often
operated in current mode.
3- Pulse mode detectors measure the average current over many interactions.
4- The amplitude of the signal in the pulse mode is proportional to the charge
generated within the detector.
5- The sensitivity in the current mode is many factors greater than when using pulse
mode.
6- The information on individual pulse amplitude is lost in the current mode.
7- Peaks in the DPHS indicate pulse amplitude about which few pulses occur.
8- Valleys appear in DPHS means a region of maximum slope observed in the
integral distribution.
9- Minimum sensitivity to drifts in discrimination level is achieved at the plateaus
of the counting curves.
10- When the value of the resolution decreased, the resolution of the detector
decreased too.
11- The statistical noise in the detectors is arising from the drift of operating
conditions.
12- In non-paralyzable detectors, the true events which occur during the dead
period are assumed to further extend the dead time.
13- Two-source method provides a test for the validity of the assumed dead time
model.
Transcribed Image Text:Q1: Answer by YES or NO for the following sentences: 1- Detectors that are applied to radiation dosimetry are often used in pulse mode. 2- Radiation detectors used for nuclear reactors' power monitoring are most often operated in current mode. 3- Pulse mode detectors measure the average current over many interactions. 4- The amplitude of the signal in the pulse mode is proportional to the charge generated within the detector. 5- The sensitivity in the current mode is many factors greater than when using pulse mode. 6- The information on individual pulse amplitude is lost in the current mode. 7- Peaks in the DPHS indicate pulse amplitude about which few pulses occur. 8- Valleys appear in DPHS means a region of maximum slope observed in the integral distribution. 9- Minimum sensitivity to drifts in discrimination level is achieved at the plateaus of the counting curves. 10- When the value of the resolution decreased, the resolution of the detector decreased too. 11- The statistical noise in the detectors is arising from the drift of operating conditions. 12- In non-paralyzable detectors, the true events which occur during the dead period are assumed to further extend the dead time. 13- Two-source method provides a test for the validity of the assumed dead time model.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Pressure sensors
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,