On a 120/240 V, single-phase, three-wire system, identify the following: a. Voltage between one grounded conductor and one ungrounded conductor b. Voltage between two ungrounded conductors.
Q: Which part of a lightning protection system is at the top of the structure? A. Ground terminal…
A: According to the question we have discuss about the lighting protection system.
Q: What is the minimum-size supply-side bonding jumper required if installed on the line side of a…
A: The supply-side bonding jumper is installed on the line side of a 300-ampere service disconnecting…
Q: 23. A grounding conductor helps prevent a shock hazard in the event that an ungrounded, or hot,…
A: The explanation is as follows.
Q: The insulation rating of class 3, PLTC, FPL, CM cables rated at ____ volts.
A: Ans. 300 volts
Q: 4. What can installation records be used to determine while servicing equipment? A. Broken…
A: Installation record refers to an information of equipment ratings, measurement, etc. which is…
Q: The NEC requires the grounded conductors to be routed to the service disconnecting means enclosure…
A: According to the NEC article code 250.186 (B), "System with a grounded conductor at the service…
Q: 1. Circuit breakers should be included in the impedance diagram. (True/False)
A: SINGAL LINE DIAGRAM OF A POWER SYSTEM: A single line diagram is the representation of a power system…
Q: On your own understanding, what is solid wire conductor and stranded wire conductor and where are…
A: The explanation is as follows.
Q: Give the raceway size required for each of the following conductor combinations: 1. Five, 10 AWG,…
A: The raceway size required for each of the following conductor combination is given as per the…
Q: an unintentional electrically conducting connection between and ungrounded conductor of an…
A: The fault occurs due to connection between the ungrounded conductor and the metallic raceways,…
Q: Q.4. Mention the specifications of EIA/TIA recognized cables and its standard number for each type…
A: With industry input, the TIA/EIA cable standards have been developed by the Telecommunications…
Q: 8- Generally as of the operating voltage which of the following options are the correct words that…
A:
Q: 5. In a solidly grounded electrical system with a phase-to-phase voltage of 4160 volts and a…
A: Given that : Phase to phase voltage =4160 volts phase to ground voltage of 2400 volts voltage level…
Q: 5. How many system bonding jumpers normally are there for a separately derived system that's…
A: We are authorized to answer only 1 question at a time since you have not mentioned which question…
Q: A(n) _________ is a reliable conductor used to ensure the required electrical conductivity between…
A: The explanation is as follows.
Q: Label the parts of Tubular Steel Poles
A: Steel tabular poles are not commonly used poles these poles are used when there is need of low cost…
Q: The floating power supply is a method for anti-interference in which neither of the conductors is…
A: The floating power supply is nothing but neither of the conductors is connected to the line carrying…
Q: Why ACSR Conductors are preferred over Copper Conductors? Note please don’t handwringing.
A: The explanation is as follows.
Q: A conductor with continuous white or gray covering shall be used only for the grounded circuit…
A: According to article NEC 200.6, the facts about the identification of the Grounded conductors are…
Q: How many outlets can be connected to a lighting line in a single-phase system
A: Choose the correct option How many outlets can be connected to a lighting line in a single-phase…
Q: How far can a 230V, 50A, three-phase load be located from a panelboard if it's fed with 3 AWG…
A: The Length of the load from the panel board is calculated as shown below
Q: What type of bonding jumper connects the grounded circuit conductor and the equipment grounding…
A: In a power system , Main bonding jumper connects the grounded circuit conductor and the equipment…
Q: Four No. 12 and four No. 10 conductors are to be installed in a EMT conduit 600 V jacketed. What…
A: Given four No. 12 and four No. 10 conductors are to be installed in a EMT conduit 600 V jacketed. We…
Q: Explain the two main testing process used in testing transmission cables.
A: Fiber optics is a technology that is connected with the transmission of information as light rays…
Q: Some electricians do not bother to calculate the minimum size of neutral service conductor. They…
A: 3-phase star connection balanced system does not require a neutral wire in the system. Basically, in…
Q: Describe some of the factors that have contributed to the delays in undersea cable maintenance.
A: The underground cables play a major role in the internet flow in many of the country's.They are a…
Q: 8. How do the terms ‘impedance drop’, ‘voltage drop’ and ‘voltage regulation’, in connection of…
A: Impedance drop: Impedance drop is the product of the current and the internal impedance. The…
Q: Discuss Suspension insulators are recommended in high voltage transmission lines.
A: Pin encasings become excessively cumbersome an uneconomical past 33 kV. Thus, for voltages higher…
Q: 20. If a cable assembly such as a metal-clad (MC) cable includes an equipment grounding conductor…
A: given a mcq on optical cables and the coloured used for MC cables.
Q: In terminating the coaxial cable, If the present procedure is to loosen up the braided shield and…
A: In terminating the coaxial cable, the the flaring and bending back the outer braid onto the cable…
Q: Identify the minimum distance requirements between network cables and power sources and identify…
A: 50 mm is the minimum distance required between the power source and network cables.
Q: b) Why Generation Voltage Levels are low in the range of 11 kV/ 33 kV etc? c) Why ACSR Conductors…
A: b) we know that the voltage drop in line depecds upon various factors such as:- Load value, load…
Q: 19.a. Which term relates to the conductors connected to the output side of a separately derived…
A: A power station is to provide electricity to a huge number of people. Different customer’s power…
Q: Explain why the low voltage problem at higher loading is more severe in an uncompensated over-head…
A: You have asked multiple independent questions. We are authorized to answer one question at a time.…
Q: Explain some of the factors that have contributed to the delays in undersea cable maintenance.
A: Communication is the exchange of information. Information can be imparted to either individuals or a…
Q: What is the rated ampacity per phase for six No. 3/0 THHN copper current-carrying conductors with…
A: Ampacity: The maximum current that a conductor can carry continuously under normal operating…
Q: separable
A: Given that Which of the following conductors in a typical separable connection plug and receptacle…
Q: When selecting conductors, from where is the motor full - load ampere rating to be taken
A: During the selection of the conductors, the motor full-load ampere rating is taken in the squirrel…
Q: advanced equipment 15. The supply systems for sensitive electronic equipment are _______ systems.…
A: LCD TVs, computers,s and plasma TVs are examples of sensitive electronic equipment.n phase required…
Q: define circuit breaker? Sfs circuit breaker? method for arc interaction in circuit breaker
A: When circuit breaker operates and open its contact then arc occurs between the contact terminals.…
Q: What is the largest solid (not stranded) conductor approved for installation in raceways?
A: Solid conductor are made with a single conductive material while stranded conductor are made with…
Q: How to verify the validity of the nodal analysis technique in solving electrical networks?
A: Given: Brief description: In the above question they want to discuss the nodal analysis technique…
Q: is the required size of THHN copper conductors for a feeder serving two 208Y/120V, four-wire,…
A:
Q: Explain why the low voltage problem at higher loading is more severe in an uncompensated over-head…
A:
Q: How many 14 AWG THHN conductors, including an equipment grounding conductor, can be installed in a…
A: Here we have to refer standard tables, When determining the maximum number of conductors permitted…
Q: procedure for UG cable Joining?
A: It is asked to explain the procedure underground (UG) cable joining.
Q: What size equipment grounding conductor is used with # 8 AWG nonmetallic-sheathed cable
A: The minimum size equipment grounding conductor is selected on the basis of the current rating…
Q: Why do multiple conductors in dc, 1-phase, and 3-phase power cables not disturb the magnetic compass…
A: Multiple conductors in DC, 1- phase, or 3 phase power cables do not disturb the magnetic compass…
Q: What is the rated amps city per phase for six No. 3 THHN copper current-carrying conductors with two…
A: Conductor amps city -- The amps city of six No. 3 THHN conductor installed in the same raceway must…
On a 120/240 V, single-phase, three-wire system, identify the following: a. Voltage between one grounded conductor and one ungrounded conductor b. Voltage between two ungrounded conductors.
Trending now
This is a popular solution!
Step by step
Solved in 2 steps with 2 images
- 3. With respect to conductor insulation, describe the following location ratings: a. Dry b. Damp c. WetThe three bus-bar conductors in an outdoor sub-station are supplied by units of post insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station.A set of conductors is used to supply residential unit with a total load current of 60 A at a single-phase supply voltage of 230 V. What would be the minimum size of the conductor to be used to achieve at least 5% voltage drop? The total conductor length is 300 ft. ..
- b) Why Generation Voltage Levels are low in the range of 11 kV/ 33 kV etc? c) Why ACSR Conductors are preferred over Copper Conductors?3. The three bus-bar conductors in an outdoor sub-station are supplied by units ofpost insulators. Each unit consists of a stack of 3-pin insulators fixed one on the top of the other. The voltage across the lowest insulator is 8-45 kV and that across the next is 7-25 kV. Find the bus-bar voltage of the station. [38-8 kV]c.1. Which of the following is one of the three essential functions of an equipment grounding conductor?A. Provide an arc-fault current pathB. Establish groundingC. Establish bondingD. Ensure the system is groundedc.2. What's another name for the three-point method of Earth resistance testing?A. Fall-of-potentialB. Line surgeC. Spatial shieldingD. Leakage current c.3. If the National Electrical Code provides a requirement to ground equipment, it generally implies thatthere will be a direct connection to the Earth of a connection through a/anA. grounding electrode conductor.B. equipment grounding conductor.C. equipotential bonding conductor.D. bonding conductor.
- The minimum size raceway for the following feeder conductors is: a. Three, 250 kcmil conductors with XHHW insulation b. One, 3/0 AWG conductor with XHHW insulation c. One, 4 AWG conductor with XHHW insulation The minimum size raceway for the following branch circuit conductors is: a. Twelve, 6 AWG conductors with THHN insulation b. Nine, 8 AWG conductors with THHN insulation c. Eighteen, 10 AWG conductor with THHN insulation d. One, 10 AWG equipment grounding conductor with THHN insulation15. Which of the following conductors in a typical separable connection plug and receptacle has a firstmake, last-break feature?A. The neutral grounded conductorB. The equipment grounding conductorC. A center wye conductorD. The grounded delta conductor9. Which grounding method is typically required of higher-voltage systems? A. Grounding through inductorsB. Grounding through a low amount of resistanceC. Grounding through a high-impedance device D. Grounding through surge arresters 10. Which term relates to the conductors connected to the output side of a separately derived system? A. Neutral conductorB. Transformer secondary conductorC. System conductor D. Derived phased conductor 11. If there's no service disconnect at a remotely supplied building, then the grounding electrode conductor and the equipment grounding conductor can be bonded together at a A. junction box.B. structural steel location. C. grounding electrode rod. D. water line. 12. In a DC system, the bonding jumper between the negative of the supply and ground is normally made at the source or at the A. first disconnecting means. B. first device on the supply. C. end of the DC line.D. entrance to the building. 13. Which of the following is a common raceway…
- Count the neutral conductor of a 4-wire, 3-phase, wye-connected circuit when the major portion of the load is electric discharge lighting (fluorescent, mercury vapor, high-pressure sodium, etc.), data processing, and other loads where the neutral conductor carries a. grounding b. traveler C. d. current. third harmonic unbalanced conductors to overheat but often overlooked is the possibility ofDescribe the construction and symbol of semi conductor deviceh.1. In an alternating-current system, the maximum size for a copper grounding electrode conductor isA. 250 kcmil.B. 3/0.C. 500 kcmil.D. 4/0. h.2. The figure shows a fault condition in an ungrounded electrical system. Which of the following will occurbecause of the fault in this system?A. Only the overcurrent protector at Point A will trip open.B. The ground fault will heavily damage the service.C. Nothing will happen until a second ground fault occurs.D. The overcurrent protection will trip, shutting off all the line side power.