Kust do l18 11.8 The synchronous generator in Figure 11.4 delivers 0.8 per-unit real power at 1.05 per-unit terminal voltage. Determine: (a) the reactive power output of the generator; (b) the generator internal voltage; and (c) an equation for the electrical power delivered by the generator versus power angle 8. 11.9 The generator in Figure 11.4 is initially operating in the steady-state con- dition given in Problem 11.8 when a three-phase-to-ground bolted short circuit occurs at bus 3. Determine an equation for the electrical power delivered by the generator versus power angle & during the fault. FIGURE 11.4 2 Single-line diagram for Example 11.3 B12 B21 X12 = 0.20 G XR = 0.10 811 X = 0.30 3 Veus 10 B22 F X13 = 0.10 X23 0.20 813

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter7: Symmetrical Faults
Section: Chapter Questions
Problem 7.3MCQ: The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of...
icon
Related questions
Question
i need the answer quickly
Just do 118
11.8 The synchronous generator in Figure 11.4 delivers 0.8 per-unit real power
at 1.05 per-unit terminal voltage. Determine: (a) the reactive power output
of the generator; (b) the generator internal voltage; and (c) an equation
for the electrical power delivered by the generator versus power angle 8.
11.9 The generator in Figure 11.4 is initially operating in the steady-state con-
dition given in Problem 11.8 when a three-phase-to-ground bolted short
circuit occurs at bus 3. Determine an equation for the electrical power
delivered by the generator versus power angle & during the fault.
FIGURE 11.4
Single-line diagram
for Example 11.3
B12
B21
X12 = 0.20
G XTR = 0.10
X; = 0.30
B11
3
VEus = 1.0
B22
F
X13 = 0.10
X23 - 0.20
B13
Transcribed Image Text:Just do 118 11.8 The synchronous generator in Figure 11.4 delivers 0.8 per-unit real power at 1.05 per-unit terminal voltage. Determine: (a) the reactive power output of the generator; (b) the generator internal voltage; and (c) an equation for the electrical power delivered by the generator versus power angle 8. 11.9 The generator in Figure 11.4 is initially operating in the steady-state con- dition given in Problem 11.8 when a three-phase-to-ground bolted short circuit occurs at bus 3. Determine an equation for the electrical power delivered by the generator versus power angle & during the fault. FIGURE 11.4 Single-line diagram for Example 11.3 B12 B21 X12 = 0.20 G XTR = 0.10 X; = 0.30 B11 3 VEus = 1.0 B22 F X13 = 0.10 X23 - 0.20 B13
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
8086 Microprocessor
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning