Estimate cell temperature, open-circuit voltage, and maximum power output for the KD230GX-LPB module under conditions of 1- sun insolation and ambient temperature 30°C. The module has a NOCT of 47°C. Ans. Cell temperature = 64°C, maximum power = 189.6 W, open circuit voltage = 31.7 V. Estimate the cell temperature and power delivered by a 100-W PV module with the following conditions. Assume 0.5%fC power loss. a. NOCT = 50°C, ambient temperature of 25°C, insolation of 1-sun. b. NOCT = 45°C, ambient temperature of 0°C, insolation of 500 W/m2. c. NOCT = 45°C, ambient temperature of 30°C, insolation of 800 W/m².

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.30P: Reconsider Problem 3.29. If Va,VbandVc are a negative-sequence set, how would the voltage and...
icon
Related questions
Question
10:42
Yo) a ll 92% 2
LTÉ
Sri Sangamesh Goudappanavar started recording
UEE741E-3C_Unit1-Chap2 - PowerPoint
Suresh Jangamshetti
imations
Slide Show
Review
View
Recording
Help
Acrobat
Tell me what you want to do
A A E
O Shape Fill -
P Find
Shape Outline -
Sac Replace
ab
Shapes Arrange Quick
Styles
aby
A -
Shape Effects
E Select
Paragraph
Drawing
Editing
1
1
2..
4
PES
Examples
Estimate cell temperature, open-circuit voltage, and maximum
power output for the KD230GX-LPB module under conditions of 1-
sun insolation and ambient temperature 30°C. The module has a
NOCT of 47°C.
Ans. Cell temperature = 64°C, maximum power = 189.6 W, open circuit
voltage = 31.7 V.
Estimate the cell temperature and power delivered by a 100-W PV module
with the following conditions. Assume 0.5%fC power loss.
a. NOCT = 50°C, ambient temperature of 25°C, insolation of 1-sun.
b. NOCT = 45°C, ambient temperature of 0°C, insolation of 500 W/m².
c. NOCT = 45°C, ambient temperature of 30°C, insolation of 800 W/m².
Ans.
a) T= 62.5°C, P = 81.25 W
b) T= 15.6°C, P = 52.35 W
c) T= 55°C, P = 68 W
39
= Notes
Display Settings
Comments
29°C
SHJ
•..
BH
BG
BU...
RAMESH V. ☆ POOJA PA..
SHJ
Transcribed Image Text:10:42 Yo) a ll 92% 2 LTÉ Sri Sangamesh Goudappanavar started recording UEE741E-3C_Unit1-Chap2 - PowerPoint Suresh Jangamshetti imations Slide Show Review View Recording Help Acrobat Tell me what you want to do A A E O Shape Fill - P Find Shape Outline - Sac Replace ab Shapes Arrange Quick Styles aby A - Shape Effects E Select Paragraph Drawing Editing 1 1 2.. 4 PES Examples Estimate cell temperature, open-circuit voltage, and maximum power output for the KD230GX-LPB module under conditions of 1- sun insolation and ambient temperature 30°C. The module has a NOCT of 47°C. Ans. Cell temperature = 64°C, maximum power = 189.6 W, open circuit voltage = 31.7 V. Estimate the cell temperature and power delivered by a 100-W PV module with the following conditions. Assume 0.5%fC power loss. a. NOCT = 50°C, ambient temperature of 25°C, insolation of 1-sun. b. NOCT = 45°C, ambient temperature of 0°C, insolation of 500 W/m². c. NOCT = 45°C, ambient temperature of 30°C, insolation of 800 W/m². Ans. a) T= 62.5°C, P = 81.25 W b) T= 15.6°C, P = 52.35 W c) T= 55°C, P = 68 W 39 = Notes Display Settings Comments 29°C SHJ •.. BH BG BU... RAMESH V. ☆ POOJA PA.. SHJ
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps

Blurred answer
Knowledge Booster
Single phase transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning