Draw the free body diagram of the structure with correct dimensions. Present TWO possible load cases that could cause the structure to overturn or lose its static equilibrium. Provide clear labelling for "unfavourable", "favourable", "leading", and "accompanying". Write clearly the values of partial safety factor for loads and indicate the point of overturning in the footing foundation. Calculate the largest weight of foundation required in kN that will ensure static equilibrium in this structure for the worst possible load case.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
QUESTION 2
Consider roof structure in a petrol kiosk as shown in Figure Q2. The overall height is 6 m and the width
of the roof cantilevers out 3 m each on both sides making a total width of 6 m. The footing foundation
at the base of the column has a depth of 3 m and a width of 2 m. Given the following characteristic
actions acting on the structure:
(a)
(b)
Characteristic permanent action on roof (includes self-weight) =
Characteristic variable action on roof (non-accessible)
Characteristic wind action (acting horizontally along the height) =
(c)
Figure Q2. Roof structure in petrol kiosk
Solve the following questions based on the limit state concept for static equilibrium of structure (EQU)
with reference to Table A1.2(A) BS EN 1990.
20 kN/m
5 kN/m
10 kN/m
Draw the free body diagram of the structure with correct dimensions.
Present TWO possible load cases that could cause the structure to overturn or lose its static
equilibrium. Provide clear labelling for "unfavourable", "favourable", "leading", and
"accompanying". Write clearly the values of partial safety factor for loads and indicate the
point of overturning in the footing foundation.
Calculate the largest weight of foundation required in KN that will ensure static equilibrium in
this structure for the worst possible load case.
Transcribed Image Text:QUESTION 2 Consider roof structure in a petrol kiosk as shown in Figure Q2. The overall height is 6 m and the width of the roof cantilevers out 3 m each on both sides making a total width of 6 m. The footing foundation at the base of the column has a depth of 3 m and a width of 2 m. Given the following characteristic actions acting on the structure: (a) (b) Characteristic permanent action on roof (includes self-weight) = Characteristic variable action on roof (non-accessible) Characteristic wind action (acting horizontally along the height) = (c) Figure Q2. Roof structure in petrol kiosk Solve the following questions based on the limit state concept for static equilibrium of structure (EQU) with reference to Table A1.2(A) BS EN 1990. 20 kN/m 5 kN/m 10 kN/m Draw the free body diagram of the structure with correct dimensions. Present TWO possible load cases that could cause the structure to overturn or lose its static equilibrium. Provide clear labelling for "unfavourable", "favourable", "leading", and "accompanying". Write clearly the values of partial safety factor for loads and indicate the point of overturning in the footing foundation. Calculate the largest weight of foundation required in KN that will ensure static equilibrium in this structure for the worst possible load case.
3m
3m-
-3m-
Unfar.
1.5m
f
$
f
2023.11.01 09:52
ZM
1.5m
Fav.
mun
1.5m 1.5m
*
0.5m Im Im 0.5m
-+-+
ZM
t
use this to
find worst
Gk.
for the TWO CASES.
Transcribed Image Text:3m 3m- -3m- Unfar. 1.5m f $ f 2023.11.01 09:52 ZM 1.5m Fav. mun 1.5m 1.5m * 0.5m Im Im 0.5m -+-+ ZM t use this to find worst Gk. for the TWO CASES.
Expert Solution
steps

Step by step

Solved in 4 steps with 6 images

Blurred answer
Knowledge Booster
Roofing elements and materials
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning