An oil is being cooled in certain equipment. It was observed that a 7.94 bmin of hot oil enters a negligible diameter thickness metal pipe of D= 25 mm. At the same time same mass of cooling water flows through the annular space between the pipe and a larger concentric pipe; the oil and water moving in opposite directions. The oil enters at 420 K and is to be cooled to 320 K. If the water enters at 290 K, what length of pipe will be required? Take coefficients of 1.6 kWim? K on the oil side and 3.6 KWim? K on the water side and 2.0 kJ/kg K for the specific heat of the oil. a. 1.9 m & 3.5 m b. 4.8 m d. 2.7 m

Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Chapter1: Introduction
Section: Chapter Questions
Problem 1.1P
icon
Related questions
Question

please answer thank you

An oil is being cooled in certain equipment. It was observed that a 7.94 b/min of hot oil enters a negligible diameter thickness metal pipe of D= 25 mm.
At the same time same mass of cooling water flows through the annular space between the pipe and a larger concentric pipe; the oil and water moving
in opposite directions. The oil enters at 420 K and is to be cooled to 320 K. If the water enters at 290 K, what length of pipe will be required? Take
coefficients of 1.6 kW/m? K on the oil side and 3.6 kWim? K on the water side and 2.0 kJ/kg K for the specific heat of the oil.
a. 1.9 m
& 3.5 m
b. 4.8 m
d. 2.7 m
Transcribed Image Text:An oil is being cooled in certain equipment. It was observed that a 7.94 b/min of hot oil enters a negligible diameter thickness metal pipe of D= 25 mm. At the same time same mass of cooling water flows through the annular space between the pipe and a larger concentric pipe; the oil and water moving in opposite directions. The oil enters at 420 K and is to be cooled to 320 K. If the water enters at 290 K, what length of pipe will be required? Take coefficients of 1.6 kW/m? K on the oil side and 3.6 kWim? K on the water side and 2.0 kJ/kg K for the specific heat of the oil. a. 1.9 m & 3.5 m b. 4.8 m d. 2.7 m
Expert Solution
steps

Step by step

Solved in 4 steps

Blurred answer
Recommended textbooks for you
Introduction to Chemical Engineering Thermodynami…
Introduction to Chemical Engineering Thermodynami…
Chemical Engineering
ISBN:
9781259696527
Author:
J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:
McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind…
Elementary Principles of Chemical Processes, Bind…
Chemical Engineering
ISBN:
9781118431221
Author:
Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:
WILEY
Elements of Chemical Reaction Engineering (5th Ed…
Elements of Chemical Reaction Engineering (5th Ed…
Chemical Engineering
ISBN:
9780133887518
Author:
H. Scott Fogler
Publisher:
Prentice Hall
Process Dynamics and Control, 4e
Process Dynamics and Control, 4e
Chemical Engineering
ISBN:
9781119285915
Author:
Seborg
Publisher:
WILEY
Industrial Plastics: Theory and Applications
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:
9781285061238
Author:
Lokensgard, Erik
Publisher:
Delmar Cengage Learning
Unit Operations of Chemical Engineering
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:
9780072848236
Author:
Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:
McGraw-Hill Companies, The