An aluminum alloy [E = 10,000 ksi; ơy = 40 ksi] pipe (1) is connected to a bronze [E = 16,000 ksi; Oy=45 ksi] pipe at flange B, as shown in Figure P5.25. The pipes are attached to rigid supports at A and C. Pipe (1) has an outside diameter of 2.375 in., a wall thickness of 0.203 in., and a length of L1 = 6 ft. Pipe (2) has an outside diameter of 4.50 in., a wall thickness of 0.226 in., and a length of L2 = 10 ft. If a minimum factor of safety of 1.67 is required for each pipe, determine: (a) the maximum load P that may be applied at flange B. (b) the deflection of flange B at the load determined in part (a). %3D %3D

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
(1)
(2)
B
C
L,
L2
FIGURE P5.25
Transcribed Image Text:(1) (2) B C L, L2 FIGURE P5.25
An aluminum alloy [E = 10,000 ksi; oy = 40 ksi] pipe (1)
is connected to a bronze [E =16,000 ksi; ơy= 45 ksi] pipe
at flange B, as shown in Figure P5.25. The pipes are
attached to rigid supports at A and C. Pipe (1) has an
outside diameter of 2.375 in., a wall thickness of 0.203 in.,
and a length of L1 = 6 ft. Pipe (2) has an outside diameter
of 4.50 in., a wall thickness of 0.226 in., and a length of L2
10 ft. If a minimum factor of safety of 1.67 is required
for each pipe, determine:
(a) the maximum load P that may be applied at flange B.
(b) the deflection of flange B at the load determined in
part (a).
%3D
1:46 PM
49°F Sunny
2/17/2022
P Type here to search
End
F10
PgUP 1
PgDn
PrtScn
F8
Home
F9
DII
F4
F3
Esc
2$
%
Transcribed Image Text:An aluminum alloy [E = 10,000 ksi; oy = 40 ksi] pipe (1) is connected to a bronze [E =16,000 ksi; ơy= 45 ksi] pipe at flange B, as shown in Figure P5.25. The pipes are attached to rigid supports at A and C. Pipe (1) has an outside diameter of 2.375 in., a wall thickness of 0.203 in., and a length of L1 = 6 ft. Pipe (2) has an outside diameter of 4.50 in., a wall thickness of 0.226 in., and a length of L2 10 ft. If a minimum factor of safety of 1.67 is required for each pipe, determine: (a) the maximum load P that may be applied at flange B. (b) the deflection of flange B at the load determined in part (a). %3D 1:46 PM 49°F Sunny 2/17/2022 P Type here to search End F10 PgUP 1 PgDn PrtScn F8 Home F9 DII F4 F3 Esc 2$ %
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Buckling of Columns
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY