A short transmission line connects a step-up transformer on the source side with a series impedance of j0.5 ohms (referred to the primary) to a step-down transformer on the load side with a series impedance of 50 ohms (referred to the primary). The turn ratio of the step-up transformer is 1:10 and a no-load primary voltage of 13.2 (line-to-line) kV. The step-down transformer has a turn ratio of 15:1 and it has a Y-connected, balanced load of 0.667 +j 0.111 ohms connected to its secondary side. Assuming an ideal transmission line, the effective impedance of the system seen by the source would be: A. 7.65 + j0.883 B. 15 + j12.5 C. None of the other choices are correct D. 0.765 + j0.883 E. 1.5 +j1.25
A short transmission line connects a step-up transformer on the source side with a series impedance of j0.5 ohms (referred to the primary) to a step-down transformer on the load side with a series impedance of 50 ohms (referred to the primary). The turn ratio of the step-up transformer is 1:10 and a no-load primary voltage of 13.2 (line-to-line) kV. The step-down transformer has a turn ratio of 15:1 and it has a Y-connected, balanced load of 0.667 +j 0.111 ohms connected to its secondary side. Assuming an ideal transmission line, the effective impedance of the system seen by the source would be: A. 7.65 + j0.883 B. 15 + j12.5 C. None of the other choices are correct D. 0.765 + j0.883 E. 1.5 +j1.25
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.26P: A bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a...
Related questions
Question
A short transmission line connects a step-up transformer on the source side with a series impedance of j0.5 ohms (referred to the primary) to a step-down transformer on the load side with a series impedance of 50 ohms (referred to the primary). The turn ratio of the step-up transformer is 1:10 and a no-load primary voltage of 13.2 (line-to-line) kV. The step-down transformer has a turn ratio of 15:1 and it has a Y-connected, balanced load of 0.667 +j 0.111 ohms connected to its secondary side. Assuming an ideal transmission line, the effective impedance of the system seen by the source would be:
A. 7.65 + j0.883
B. 15 + j12.5
C. None of the other choices are correct
D. 0.765 + j0.883
E. 1.5 +j1.25
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution!
Trending now
This is a popular solution!
Step by step
Solved in 4 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning