A 50-MVA, 30-kV, three-phase synchronous generator has a synchronous reactance of 8 Ohms/phase and negligible armature resistance. The generator is delivering 50 MVA at 0.8 pf leading to an infinite bus at the rated voltage. Determine the excitation per phase E and the power angle 8. Select one: O a. E = 22.78 KV and 8= 15.67 deg. O b. E = 14.115 KV and 8= 25.85 deg. O c. None of these O d. E = 13.96KV and 8= 29.74 deg. O e. E = 27.47KV and 8= 22.84 deg.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
A 50-MVA, 30-kV, three-phase synchronous generator has a synchronous reactance of 8 Ohms/phase and negligible
armature resistance. The generator is delivering 50 MVA at 0.8 pf leading to an infinite bus at the rated voltage.
Determine the excitation per phase E and the power angle &.
Select one:
O a. E = 22.78 KV and 8= 15.67 deg.
O b. E = 14.115 KV and 8= 25.85 deg.
O c. None of these
O d. E = 13.96KV and 8= 29.74 deg.
O e. E = 27.47KV and 8= 22.84 deg.
Impedances are marked in perunit on a 100MVA, 100 KV base. The load at bus 2 is S2= 16MW - 132 MVAR, and the load at
EN ?
1:4
4/1-
TOSHIBA
Transcribed Image Text:A 50-MVA, 30-kV, three-phase synchronous generator has a synchronous reactance of 8 Ohms/phase and negligible armature resistance. The generator is delivering 50 MVA at 0.8 pf leading to an infinite bus at the rated voltage. Determine the excitation per phase E and the power angle &. Select one: O a. E = 22.78 KV and 8= 15.67 deg. O b. E = 14.115 KV and 8= 25.85 deg. O c. None of these O d. E = 13.96KV and 8= 29.74 deg. O e. E = 27.47KV and 8= 22.84 deg. Impedances are marked in perunit on a 100MVA, 100 KV base. The load at bus 2 is S2= 16MW - 132 MVAR, and the load at EN ? 1:4 4/1- TOSHIBA
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Magnetic moment
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,