1. What are the features of star and delta connected windings?
Q: Explain how Y-connected stator winding of alternator requires 58% of turns with respect to that of…
A:
Q: Inter pole winding is connected in - series with armature O series with main poles parallel with…
A: Interpole Winding: - An interpole winding is connected to minimise the effect of armature reaction.…
Q: Practice Problem 1,2 A 60 - cycle, 150 kVA, three winding transformer is rated at 4,800 volts…
A:
Q: Neatly please 4. Draw the the two types of Compounded wiring diagram of DC Generator
A:
Q: EXERCISE PROBLEMS 6. A single-phase, 50 Hz transformer has 40 primary turns and 520 secondary turns.…
A:
Q: How the fractional slot winding is constructed? give map of winding at least two pole pitches in the…
A: The windings used in rotating electrical machines can be classified asConcentrated Windings• All the…
Q: (a) Explain why the magnetising current of a transformer is less than that of an equivalent rotating…
A: Introduction: Transformer is the device that steps up or steps down the level of voltage. There are…
Q: Q/ A 40-kVA, 3,300/240-V, 50 Hz, 1-phase transformer has 660 turns on the primary. Determine: (a)…
A: Given, A 40-kVA, 3300/240 V. 50 Hz 1-phase transformer, E1E2=3300 V240 V Primary turns, N1= 600
Q: 2. What will happen if transformers are connected in parallel without satisfying the necessary…
A: Transformer parallel connection
Q: 1- The resistance of secondary windings of step-down transformer is resistance of secondary…
A: Need to fill the blank
Q: 1. When a transformer is supplied at 400 V, 50 Hz, the hysteresis loss is found to be 310 W and eddy…
A: Given: At V1=400 V and f1=50 Hz Hysteresis loss, Ph1=310 W and Eddy current loss is, Pe1=260 W At…
Q: Hoq do current transformers differ from voltage transformers?
A: Current Transformer is used to measure current while, Voltage transformer is used to measure…
Q: 1- When 400 volts, 60HZ is applied to the transformer primary winding maximum flux in the core is---
A: We know that Emf Equation: E=4.44NBAf=4.44 Nfϕ E=v= voltage or emf N= no. of turns B=magnetic flux…
Q: 4- The step-down transformer ?
A: Electrical machines can be either generator, motors or transformers. They can be either Ac machines…
Q: A single phase transformer has 400 primary and 1000 secondary turns. The net cross-sectional area of…
A:
Q: Q1: What is the influence of transformer connections in single-phase transformers connected for 3-…
A: According to the Bartleby guidelines “Since you have asked multiple question, we will solve the…
Q: Assume a single phase transformer with primary and secondary winding. Explain what would happen if a…
A: Transformer is a static device which is used to step up/down the voltage or current level without…
Q: What are the reasons for using transformer oil in power transformers and why are mineral oils…
A: The explanation is as follows.
Q: Three Phase Transformer connections: Discuss Fully the various methods available for transforming…
A: The methods of transformation of a 3-phase voltage into higher or lower 3-phase voltages is done…
Q: voltage per winding of the 220V/12V, 60 Hz single phase core transformer is 2V. If the maximum flux…
A: We know direct formula of per winding voltage. From that formula we will find out cross section…
Q: What way the two electrical circuits are linked in transformer to change the values of alternating…
A:
Q: Given this transformer with load, what is the expected phase of the primary and secondary voltage?…
A: The solution is provided in the following section.
Q: 5-Questions : 1- What are the advantages of Transformer Tests?
A: We’ll answer the first question since the exact one wasn’t specified. Please submit a new question…
Q: transformer the core loss is 100 watt at 40 Hz and 72 watt at 37 Hz, then eddy current and…
A: In this question , we have to find out Eddy current losses and hysteresis losses...
Q: Power transformer divided into two categories which are dry type and oil-immersed transformer, with…
A: You have asked multiple independent questions. We are authorized to answer one question at a time.…
Q: B1 A single-phase, 50 Hz transformer has 30 primary turns and 420 secondary turns. The cross-…
A:
Q: Questions: 1. Why a short circuit test is done on the transformer with LV winding shorted and supply…
A:
Q: What would happen if a power transformer designed for operation on 50 Hz (frequency) were connected…
A: Solution:-The power transformer which designed for 50Hz connected to 500Hz frequency. Ex:-…
Q: A typical single-phase transformer has a certain value of voltage regulation when connected to the…
A: The problem is related to voltage regulation of transformer. The voltage regulation is positive for…
Q: A core type transformer operates on 415 / 230 volt, 55 Hz supply. If the cross-sectional area of the…
A: The number of turns in primary winding is 47. The detailed solution is provided below.
Q: Q3) What are the elements finding from no-loac test of single phase transformer? Q4) Why Transformer…
A:
Q: Why are single-phase distribution transformers made whit the low-voltage winding in two sections? A-…
A: Single-phase distribution transformers made with the low-voltage winding in two sections to minimize…
Q: Why are alternators connected in parallel? What are the conditions for parallel connection? Explain
A: The alternator is a synchronous generator that generates electricity. or it converts the mechanical…
Q: 2- What are the differences between core and shell type transformers? 3- The iron losses is constant…
A: In this question we will write about core type and shell type transformers differences....
Q: When 120 V, 60 Hz is applied to the primary winding of a transformer, the core loss is 240 W. When…
A:
Q: create block winding diagram with the given winding table on the picture below
A: Here it is asked to create a winding diagram for the given winding table. Z=10 (conductors). P=4…
Q: Q2) Draw the diagram for impedance test on transformer?
A: We test the impedance of Transformer by two test 1) Open circuit test 2) short circuit test
Q: The voltage per winding of the 220V/12V, 50 Hz single phase core transformer is 1V. If the maximum…
A:
Q: 1. What is an inter turn insulation of the transformer winding? 2. What is the common reason for…
A: Note as there are several questions and we are asked to solve one question at a time. So I am…
Q: الامتحان العملي لمادة المكائن)الفصل الاول( Q1) Draw the graph of output power versus efficiency of…
A: Since there are multiple questions uploaded so solving the first question accordingly as per the…
Q: A single-phase, 250-kVA, 11-kV/415-V, 50-Hz transformer has 80 turns on the secondary. Calculate (a)…
A: The solution is given below
Q: A core type transformer operates on 415/220 volt, 50 Hz supply. If the cross-sectional area of the…
A:
Q: 1 Normal Styles Paragraph Question 3 a) What loss does laminating the iron core of a transformer…
A: In this question we will write about what loss in transformer reduces by lamination.....
Q: 2- Why the transformer core made from lamination plates?
A: We are authorized to answer the first question since the exact one wasn’t specified. Please submit a…
Step by step
Solved in 2 steps
- In developing per-unit circuits of systems such as the one shown in Figure 3.10. when moving across a transformer, the voltage base is changed in proportion to the transformer voltage ratings. (a) True (b) FalseFor a short-circuit test on a 2-winding transformer, with one winding shorted, can you apply the rated voltage on the other winding? (a) Yes (b) NoThe ideal transformer windings are eliminated from the per-unit equivalent circuit of a transformer. (a) True (b) False
- For developing per-unit equivalent circuits of single-phase three-winding transformer, a common Sbase is selected for all three windings and voltage bases are selected in proportion to the rated voltage of the windings (a) True (b) FalseA bank of three single-phase transformers, each rated 30MVA,38.1/3.81kV, are connected in Y- with a balanced load of three 1, Y-connected resistors. Choosing a base of 90MVA,66kV for the high-voltage side of the three-phase transformer. spify the base for the low-voltage side. Compute the per-unit resistance of the load on the base for the low-voltage side. Also, determine the load resistance in ohms referred to the high-voltage side and the per-unit value on the chosen base.An ideal transformer has no real or reactive power loss. (a) True (b) False
- Three single-phase two-winding transformers, each rated 25MVA,54.2/5.42kV, are connected to form a three-phase Y- bank with a balanced Y-connected resistive load of 0.6 per phase on the low-voltage side. By choosing a base of 75 MVA (three phase) and 94 kV (line-to-line) for the high-voltage side of the transformer bank, specify the base quantities for the low-voltage side. Determine the per-unit resistance of the load on the base for the low-voltage side. Then determine the load resistance RL in ohms referred to the high-voltage side and the per-unit value of this load resistance on the chosen base.The direct electrical connection of the windings allows transient over voltages to pass through the auto transfonner more easily, and that is an important disadvantage of the autotransformer. (a) True (b) FalseConsider a bank of this single-phase two-winding transformers whose high-voltage terminals are connected to a three-phase, 13.8-kV feeder. The low-voltage terminals are connected to a three-phase substation load rated 2.0 MVA and 2.5 kV. Determine the required voltage, current, and MVA ratings of both windings of each transformer, when the high-voltage/low- voltage windings are connected (a) Y-, (b) -Y, (c) Y-Y, and (d) -.
- For an ideal 2-winding transformer, the ampere-turns of the primary winding, N1I1 is equal to the ampere-turns of the secondary winding, N2I2 (a) True (b) FalseThe ratings of a three-phase three-winding transformer are Primary(1): Y connected 66kV,15MVA Secondary (2): Y connected, 13.2kV,10MVA Tertiary (3): A connected, 2.3kV,5MVA Neglecting winding resistances and exciting current, the per-unit leakage reactances are X12=0.08 on a 15-MVA,66-kV base X13=0.10 on a 15-MVA,66-kV base X23=0.09 on a 10-MVA,13.2-kV base (a) Determine the per-unit reactances X1,X2,X3 of the equivalent circuit on a 15-MVA,66-kV base at the primary terminals. (b) Purely resistive loads of 7.5 MW at 13.2 kV and 5 MW at 2.3kV are connected to the secondary and tertiary sides of the transformer, respectively. Draw the per- unit impedance diagram, showing the per-unit impedances on a 15-MVA,66-kV base at the primary terminals.The ratings of a three-phase, three-winding transformer are Primary: Y connected, 66kV,15MVA Secondary: Y connected, 13.2kV,10MVA Tertiary: connected, 2.3kV,5MVA Neglecting resistances and exciting current, the leakage reactances are: XPS=0.09 per unit on a 15-MVA,66-kV base XPT=0.08 per unit on a 15-MVA,66-kV base XST=0.05 per unit on a 10-MVA,13.2-kV base Determine the per-unit reactances of the per-phase equivalent circuit using a base of 15 MVA and 66 kV for the primary.