17. Statements An engineer wants to design an ATES system for a large office building in a moderate climate. The annual cooling demand is 200 [MWh], the annual heating demand is 800 [MWh] too. For the heating a heat pump with SCOP 8 is coupled to the warm well. The cooling comes solely from the cold well. All heat exchangers are assumed to be perfect and there are no losses in pipes. Which of these statements are correct? (Note: multiple answers possible) 200 [MWh] heat is loaded at the warm well 100 [MWh] heat is loaded at the warm well 700 [MWh] heat is load at the warm well 800 [MWh] cold is loaded at the cold well 700 [MWh] cold is loaded at the cold well 200 [MWh] cold is loaded at the cold well To balance the ground additional cold should be loaded (e.g. by using an additional heat exchanger with cold outdoor air in winter) or the heating demand should be reduced To balance the ground additional heat should be loaded (e.g. by using additional heat exchanger coupled to a solar boiler) or the heating demand should be reduced

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.33P: Consider the three single-phase two-winding transformers shown in Figure 3.37. The high-voltage...
icon
Related questions
Question
17. Statements
An engineer wants to design an ATES system for a large office building in a moderate climate. The annual
cooling demand is 200 [MWh], the annual heating demand is 800 [MWh] too. For the heating a heat pump with
SCOP 8 is coupled to the warm well. The cooling comes solely from the cold well. All heat exchangers are
assumed to be perfect and there are no losses in pipes. Which of these statements are correct? (Note: multiple
answers possible)
200 [MWh] heat is loaded at the warm well
100 [MWh] heat is loaded at the warm well
700 [MWh] heat is load at the warm well
800 [MWh] cold is loaded at the cold well
700 [MWh] cold is loaded at the cold well
200 [MWh] cold is loaded at the cold well
To balance the ground additional cold should be loaded (e.g. by using an additional heat exchanger with
cold outdoor air in winter) or the heating demand should be reduced
To balance the ground additional heat should be loaded (e.g. by using additional heat exchanger
coupled to a solar boiler) or the heating demand should be reduced
Transcribed Image Text:17. Statements An engineer wants to design an ATES system for a large office building in a moderate climate. The annual cooling demand is 200 [MWh], the annual heating demand is 800 [MWh] too. For the heating a heat pump with SCOP 8 is coupled to the warm well. The cooling comes solely from the cold well. All heat exchangers are assumed to be perfect and there are no losses in pipes. Which of these statements are correct? (Note: multiple answers possible) 200 [MWh] heat is loaded at the warm well 100 [MWh] heat is loaded at the warm well 700 [MWh] heat is load at the warm well 800 [MWh] cold is loaded at the cold well 700 [MWh] cold is loaded at the cold well 200 [MWh] cold is loaded at the cold well To balance the ground additional cold should be loaded (e.g. by using an additional heat exchanger with cold outdoor air in winter) or the heating demand should be reduced To balance the ground additional heat should be loaded (e.g. by using additional heat exchanger coupled to a solar boiler) or the heating demand should be reduced
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Knowledge Booster
Different Types of System and Its Property
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning